Pump selection & global supply support+86 151 2119 9987 · dfin88@dfinsewagepump.com
25WQD3-9-0.37S WQ(D)-S Stainless Steel Sewage Pump

Reference image. Final construction follows the confirmed model and quotation.

Stainless Steel Submersible Pumps

25WQD3-9-0.37S WQ(D)-S Stainless Steel Sewage Pump

Model: 25WQD3-9-0.37S

25WQD3-9-0.37S 304 stainless steel pump: 3 m³/h flow, 9 m head, 0.37 kW, 220 V and 25 port size. Model-matched DFIN catalog data and product image.

TECHNICAL DATA

Specifications, performance and construction

Confirm the final operating point, materials, motor and connection standard before ordering.

25WQD3-9-0.37S product overview

The 25WQD3-9-0.37S is a all-stainless-steel sewage pump with double mechanical sealing and a wide flow channel for wastewater, fibers and suspended solids. This page presents model-specific rated data and selection information.

Model-specific technical parameters

Model25WQD3-9-0.37S
SeriesWQ(D)-S Stainless Steel Sewage Pump
Rated / maximum flow3 m³/h
Rated / maximum head9 m
Rated power0.37 kW
Rated voltage220 V
Discharge / port size25 mm
Rated speed2860 r/min
Main wetted material304 stainless steel

Design advantages

  • 304 stainless steel wetted construction
  • Double mechanical-seal protection
  • Wide flow channel for wastewater duty
  • Single-phase and three-phase model options

Typical applications

  • Building and municipal drainage
  • Factory wastewater
  • Aquaculture and farming
  • Food and beverage wastewater
  • General corrosive wastewater

WQ(D)-S Stainless Steel Sewage Pump catalog data

The following high-resolution sheets contain the product description, model code, complete series table and operating guidance for this product series.

WQ(D)-S Stainless Steel Sewage Pump technical parameters and model tableWQ(D)-S Stainless Steel Sewage Pump technical parameters and model table

Download complete DFIN English catalog (PDF) ↓

Selection and ordering information

  • Confirm required flow and total dynamic head at the duty point.
  • Confirm liquid, temperature, solids, corrosion conditions and installation method.
  • Confirm voltage, frequency, cable length, control cabinet and protection requirements.
  • For explosion-proof configurations, provide the hazardous-area classification and liquid details for engineering confirmation.

SELECTION SUPPORT

Application-based pump selection

Send the liquid, flow, head or pressure, temperature, solids, installation, power supply and destination for a verified recommendation.

Discuss this application
NEED SELECTION SUPPORT?

Send us your duty point. Our engineers will recommend a matched pump.

Talk to an engineer