IH Explosion-Proof Chemical Pump/ Stainless Steel Centrifugal Pump

Model: IH

IH Explosion-Proof Chemical Pump/ Stainless Steel Centrifugal Pump is designed for acid, alkali, solvent and process-liquid transfer. DFIN Pump provides model verification, material selection and technical support based on the actual duty point.

TECHNICAL DATA

Specifications, performance and construction

Confirm the final operating point, materials, motor and connection standard before ordering.

Product Overview

IH Explosion-Proof Chemical Pump/ Stainless Steel Centrifugal Pump is an industrial chemical pump selected for acid, alkali, solvent and process-liquid transfer. The final configuration should be verified against the actual liquid, duty point, temperature, installation and power supply.

Typical Applications

Acid, alkali, solvent and process-liquid transfer.

Design Features

  • Corrosion-resistant wetted components
  • Seal and material options
  • Industrial process compatibility
  • Model and material selection supported by DFIN Pump engineers

Extracted Operating Data

  • :2900、1450r/min :0.55~110KW :50~200mm :1.6Mpa IH 29 , 22 (2900、14
  • :6.3~400m3/ H:5~132m n:2900、1450r/min :0.55~110KW :50~200mm :1.6Mpa IH

Values are reference data from the authorized source catalog. Confirm the selected model before ordering.

Technical Performance Data

Material Name ZG1Cr18Ni9 ZG1Cr18Ni9Ti ZG0Cr18Ni12Mo2Ti
Designator 303 305 306
Material Name ZG1Cr18Ni12Mo2Ti ZG1Cr18Mn13Mo2CuN
Designator 307 402
Model Speed Flow(m3/h) Flow(L/S) Head (m) Efficiency (%) Axis Power (Kw) Equipped with Power NPSHr(m) Weight (kg)
Media density
1.0 1.35 1.85
IH50-32-125 2900 12.5 3.47 20 51 1.33 2.2 6.0 4.0 2.0 45
1450 6.3 1.74 5.0 45 0.19 0.55 0.55 0.55 2.0 45
IH50-32-160 2900 12.5 3.47 32 46 2.37 3.0 4.0 5.5 2.0 49
1450 6.3 1.74 8.0 40 0.34 0.55 0.75 1.1 2.0 49
IH50-32-200 2900 12.5 3.47 50 39 4.36 5.5 7.5 11 2.0 59
1450 6.3 1.74 12.5 33 0.65 1.1 1.1 1.5 2.0 59
IH50-32-250 2900 12.5 3.47 80 33 8.25 11 15 18.5 2.0 93
1450 6.3 1.74 20 27 1.27 2.2 2.2 3.0 2.0 93
IH65-50-125 2900 25 1.53 2.0 62 2.2 3.0 4.0 5.5 2.0 47
1450 12.5 6.94 5.0 55 0.31 0.55 0.55 0.75 2.0 47
IH65-50-160 2900 25 2.78 32 57 3.82 5.5 7.5 11 2.0 53
1450 12.5 6.94 8.0 51 0.53 0.75 1.1 1.5 2.0 53
IH65-40-200 2900 25 2.92 50 52 6.55 11 11 15 2.0 63
1450 12.5 6.94 12.5 46 0.93 1.5 2.2 2.2 2.0 63
IH65-40-250 2900 25 2.92 80 46 46 15 3.0 30 2.0 99
1450 12.5 6.94 20 39 39 2.2 37 4.0 2.0 99
IH65-40-315 2900 25 3.06 125 39 39 30 5.5 55 2.0 116
1450 12.5 6.94 32.0 33 33 5.5 5.5 7.5 2.0 116
IH80-65-125 2900 50 13.9 20 69 3.95 5.5 7.5 11 3.0 52
1450 25 6.94 5.0 64 0.53 0.75 1.1 1.5 2.5 52
IH80-65-160 2900 50 13.9 32 67 6.5 11 11 15 2.3 57
1450 25 6.94 8.0 62 0.88 1.5 1.5 2.2 2.3 57
IH80-50-200 2900 50 13.9 50 63 10.8 15 18.5 30 2.5 65
1450 25 6.94 12.5 54 0.83 1.1 1.5 2.2 2.0 65
IH80-50-250 2900 50 13.9 80 58 18.8 30 37 45 2.5 103
1450 25 6.94 20 52 2.62 4.0 5.5 7.5 2.0 103
IH80-50-315 2900 50 13.9 125 52 32.73 45 55 75 2.0 121
1450 25 6.94 32 48 4.54 7.5 7.5 11 2.0 121
IH100-80-125 2900 100 27.8 20 73 7.47 11 15 18.5 4.5 57
1450 50 13.9 5.0 68 1.0 1.5 2.2 3.0 3.5 57
IH100-80-160 2900 100 27.8 32 73 11.9 15 22 30 4.3 87
1450 50 13.9 8.0 69 1.58 2.2 3.0 4.0 3.4 87
IH100-65-200 2900 100 27.8 50 72 18.9 30 37 45 3.9 96
1450 50 13.9 12.5 68 2.5 3.0 4.0 5.5 2.5 96
IH100-65-250 2900 100 27.8 80 68 32.0 45 55 75 3.6 115
1450 50 13.9 20 63 4.3 5.5 7.5 11 2.5 115
IH100-65-315 2900 100 55.6 125 62 54.9 75 90 132 3.2 166
1450 50 27.8 32 58 7.5 11 15 18.5 2.0 166
IH125-100-200 2900 200 55.6 50 77 35.4 45 55 90 5.0 99
1450 100 27.8 12.5 73 4.66 7.5 11 15 2.9 99
IH125-100-250 2900 200 55.6 80 75 58.1 11 110 132 4.5 151
1450 100 27.8 20 72 7.56 132 15 18.5 2.3 151
IH125-100-315 2900 200 55.6 125 72 94.56 18.5 160 220 4.5 166
1450 100 27.8 32 65 13.41 18.5 22 30 2.8 166
IH125-100-400 1450 100 27.8 50 55 14.74 18.5 30 37 2.5 211
IH150-125-250 1450 200 55.6 20 77 14.1 30 30 37 2.5 165
IH150-125-315 1450 200 55.6 32 75 23.2 30 37 55 2.8 196
IH150-125-400 1450 200 55.6 50 70 38.9 55 75 90 2.8 238
IH200-150-250 1450 400 111.1 20 77 28.3 37 55 75 2.5 195
IH200-150-315 1450 400 111 32 79 44.1 55 75 110 4.0 269
IH200-150-400 1450 400 111 50 78 39.8 90 132 160 3.5 290
Possible causes of malfunction Pump cannot pump liquid Insufficient Flow and Head Power consumption is too large Produce vibration and noise Excessive leakage at seal Shaft seal (including stuffing box) heats up The pump is overheated and cannot rotate. Bearing heating and bearing wear Elimination method
Air remains in the pump or suction pipe 0 0
0
Refill pump to remove air
The suction head is too high or the perfusion is not high enough. 0 0
0
Lower the pump position and increase the pressure at the Inlet
The suction pipe passes through small or debris-filled obstructions 0 0
0

Increase the diameter of the suction pipe and remove the #plug
The suction pipe is not immersed deep enough or is leaking 0 0

Increase the immersion depth or repair the pipeline
Speed ​​is too high or too low 0 0 0


Check the prime mover Speed ​​according to the regulations.
Wrong direction of pump 0 0

adjust steering
The total Head does not match the pump Head. 0 0 0



Reduce discharge system resistance or height
The medium weight and viscosity do not meet the requirements. 0 0 0



Conversion should be done
Vibration occurs when the flow is too small and the operation is too small.


0 0
0 0 Increase flow or set up bypass circulation pipe
The axis of the pump and the motor are inconsistent or the shaft is domed.
0 0
0 0 0 Correction
There is friction between the rotating part and the fixed part

0 0

0 0 Repair the pump or improve its operating conditions
Bearings severely worn or damaged


0
0 0 0 Replace it
Seal ring worn too much
0 0




Replace it
Too much wear on the bushing, packing or dynamic and static plutonium

0
0 0 0
Replace it
Improper selection or installation of packing (or mechanical seal)

0
0 0 0
Re-select or install according to usage requirements
Unbalanced rotating parts cause vibration


0 0 0 0 0 We're trying to get rid of it.
There is too much oil in the oil chamber (or the oil is too dirty)

0 0


0 Add oil according to oil level requirements [or replace with new oil]
There is debris blocking the pipeline or pump. 0 0
0



Check and exclude
Improper seal fluid pressure



0 0

The pressure in front of the sealing chamber should be increased by 0.049~0.147MPa.
The packing gland is too tight or too loose

0
0 0

Adjust it appropriately

Selection Information Required

Please provide medium, concentration, flow, total head or pressure, temperature, viscosity or solids, voltage, frequency and installation method. DFIN Pump will confirm the suitable model and materials.

Catalog reference: authorized YZJ product data · Model IH

SELECTION SUPPORT

Application-based pump selection

Send the liquid, flow, head or pressure, temperature, solids, installation, power supply and destination for a verified recommendation.

Discuss this application
NEED SELECTION SUPPORT?

Send us your duty point. Our engineers will recommend a matched pump.

Talk to an engineer