Reference image. Final construction follows the confirmed model and quotation.
Self-Priming Pumps
JMZ Stainless Steel Self-Priming Pump/ Pump
Model: JMZ
JMZ Stainless Steel Self-Priming Pump/ Pump is designed for tank unloading, drainage, irrigation and industrial liquid transfer. DFIN Pump provides model verification, material selection and technical support based on the actual duty point.
TECHNICAL DATA
Specifications, performance and construction
Confirm the final operating point, materials, motor and connection standard before ordering.
Product Overview
JMZ Stainless Steel Self-Priming Pump/ Pump is an industrial self-priming pump selected for tank unloading, drainage, irrigation and industrial liquid transfer. The final configuration should be verified against the actual liquid, duty point, temperature, installation and power supply.
Typical Applications
Tank unloading, drainage, irrigation and industrial liquid transfer.
Design Features
- Self-priming operation
- Simple pipework arrangement
- Easy inspection and maintenance
- Model and material selection supported by DFIN Pump engineers
Extracted Operating Data
- 3m3/h-100m3/h 18m-14m 25mm-150mm
Values are reference data from the authorized source catalog. Confirm the selected model before ordering.
Technical Performance Data
|
Model |
Port Size(mm) |
Flow(m3/h) |
Head(m) | Suction Lift(m) | Motor(kw) | Rotation (r/min) |
Model |
|
| Inlet | Produced | |||||||
| 25JMZ-22 | 25 | 25 | 3 | 22 | 5 | 1.1 | 2900 | 25JMZ-22 |
| 25JMZ-30 | 25 | 25 | 3 | 30 | 6 | 1.5 | 2900 | 25JMZ-30 |
| 40JMZ-22 | 40 | 25 | 6 | 22 | 5 | 1.5 | 2900 | 40JMZ-22 |
| 40JMZ-30 | 40 | 25 | 6 | 30 | 6 | 2.2 | 2900 | 40JMZ-30 |
| 40JMZ-40 | 40 | 25 | 6 | 40 | 6 | 3 | 2900 | 40JMZ-40 |
| 50JMZ-22 | 50 | 40 | 12 | 22 | 5 | 2.2 | 2900 | 50JMZ-22 |
| 50JMZ-30T | 50 | 50 | 20 | 30 | 6 | 4 | 2900 | 50JMZ-30T |
| 50JMZ-40 | 50 | 40 | 12 | 40 | 6 | 4 | 2900 | 50JMZ-40 |
| 65JMZ-22 | 65 | 50 | 24 | 22 | 5 | 4 | 2900 | 65JMZ-22 |
| 65JMZ-30T | 65 | 65 | 30 | 30 | 6 | 5.5 | 2900 | 65JMZ-30T |
| 80JMZ-22 | 80 | 65 | 48 | 22 | 5 | 7.5 | 2900 | 80JMZ-22 |
| 80JMZ-30 | 80 | 65 | 48 | 30 | 5 | 7.5 | 2900 | 80JMZ-30 |
| 125JMZ-18 | 125 | 100 | 100 | 18 | 5 | 15 | 2900 | 125JMZ-18 |
|
Model |
Equipped with MotorKW |
L |
L1 |
L2 |
L3 |
L4 |
B |
B1 |
B2 |
B3 |
H |
H1 |
H2 |
H3 |
D1 |
D2 |
D3 |
D4 |
n×ø d |
d1 |
d2 |
|||
|
n |
ø |
quantity |
ø |
quantity |
ø |
|||||||||||||||||||
|
25JMZ-22 |
1.1 |
670 |
400 |
115 |
265 |
110 |
260 |
215 |
215 |
150 |
110 |
234 |
120 |
200 |
100 |
75 |
100 |
75 |
4 |
12 |
4 |
12 |
4 |
12 |
|
25JMZ-30 |
1.5 |
700 |
430 |
130 |
264 |
107 |
280 |
240 |
240 |
155 |
130 |
282 |
107 |
210 |
100 |
75 |
100 |
75 |
4 |
14 |
4 |
12 |
4 |
12 |
|
40JMZ-22 |
1.5 |
720 |
430 |
140 |
273 |
118 |
280 |
240 |
240 |
155 |
130 |
265 |
124 |
225 |
130 |
100 |
100 |
75 |
4 |
14 |
4 |
14 |
4 |
12 |
|
40JMZ-30 |
2.2 |
730 |
430 |
132 |
268 |
113 |
280 |
240 |
240 |
155 |
130 |
280 |
123 |
237 |
130 |
100 |
100 |
75 |
4 |
14 |
4 |
14 |
4 |
12 |
|
40JMZ-40 |
3 |
820 |
500 |
128 |
320 |
120 |
330 |
290 |
240 |
180 |
132 |
305 |
127 |
250 |
130 |
100 |
100 |
75 |
4 |
14 |
4 |
14 |
4 |
12 |
|
50JMZ-22 |
2.2 |
760 |
430 |
151 |
282 |
127 |
280 |
240 |
240 |
155 |
130 |
280 |
143 |
232 |
140 |
110 |
130 |
100 |
4 |
14 |
4 |
14 |
4 |
14 |
|
50JMZ-30T |
4 |
860 |
510 |
138 |
315 |
135 |
330 |
290 |
290 |
190 |
132 |
283 |
135 |
228 |
140 |
110 |
140 |
110 |
4 |
14 |
4 |
14 |
4 |
14 |
|
50JMZ40 |
4 |
860 |
510 |
140 |
316 |
119 |
335 |
290 |
290 |
190 |
132 |
321 |
135 |
262 |
140 |
110 |
130 |
100 |
4 |
14 |
4 |
14 |
4 |
14 |
|
65JMZ22 |
4 |
875 |
510 |
163 |
335 |
135 |
360 |
290 |
290 |
190 |
132 |
305 |
148 |
250 |
160 |
130 |
140 |
110 |
4 |
14 |
4 |
14 |
4 |
14 |
|
65JMZ30T |
5.5 |
980 |
620 |
150 |
356 |
138 |
380 |
320 |
320 |
210 |
132 |
310 |
153 |
252 |
160 |
130 |
160 |
130 |
4 |
14 |
4 |
14 |
4 |
14 |
|
80JMZ22 |
5.5 |
980 |
620 |
150 |
340 |
160 |
380 |
320 |
320 |
210 |
132 |
305 |
160 |
250 |
190 |
150 |
160 |
130 |
4 |
14 |
4 |
17.5 |
4 |
14 |
|
80JMZ30 |
7.5 |
980 |
620 |
150 |
340 |
160 |
380 |
320 |
320 |
210 |
132 |
315 |
160 |
255 |
190 |
150 |
160 |
130 |
4 |
14 |
4 |
17.5 |
4 |
14 |
|
100JMZ22 |
11 |
|
|
|
|
|
|
|
|
|
|
|
|
|
210 |
170 |
190 |
150 |
4 |
18 |
4 |
17.5 |
4 |
17.5 |
|
100JMZ30 |
15 |
|
|
|
|
|
|
|
|
|
|
|
|
|
210 |
170 |
190 |
150 |
4 |
18 |
4 |
17.5 |
4 |
17.5 |
|
150JMZ22 |
15 |
|
|
|
|
|
|
|
|
|
|
|
|
|
265 |
225 |
240 |
200 |
4 |
18 |
8 |
17.5 |
8 |
17.5 |
|
150JMZ30 |
22 |
|
|
|
|
|
|
|
|
|
|
|
|
|
265 |
225 |
240 |
200 |
4 |
18 |
8 |
17.5 |
8 |
17.5 |
|
200JMZ22 |
18.5 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
200JMZ30 |
30 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Fault |
Causes |
Troubleshooting |
|
No fluid leakage |
1. The pump is not filled with starting fluid. 2. Abortion blockage in the suction pipe, pressure pipe or pump 3. Air leakage in suction pipe 4 The suction height exceeds the allowable range 5. Using Head exceeds designing Head. 6Convey hot and volatile media 7The steering is reversed 8 Mechanical seal leaks |
1. Refill the liquid. There is no need to fill the liquid when starting the second time. 2Remove debris 3Inspect and replace the suction pipeline 4Reinstall the pump according to the allowable suction height 5Reselect the pump 6. Lower the Suction Lift or install it with reverse irrigation. 7 Correct steering 8. Repair or replace mechanical seal |
|
Long self-priming time |
1The liquid temperature is too high 2 The suction pipe is too long 3Inlet pipes have Ω-shaped bends 4Outlet submerged in liquid |
1The liquid temperature drops below 40 degrees 2. Keep the pipeline as short as possible 3Remove all omega pipes 4 Connect Outlet to the atmosphere |
|
Flow is not enough |
1 The suction pipe is not soaked deep enough 2. The suction pipe is too thin or blocked by debris. 3 The impeller is severely worn or corroded 4. The sealing ring is corroded after severe wear. 5 The gap between the impeller and the pump cover is too long |
1Increase the immersion depth of the suction pipe 2Replace appropriate pipelines and remove debris 3Replace with new impeller 4Replace with new sealing ring 5 Reduce gaps |
|
Head is not enough |
1 The impeller is severely corroded 2Motor mismatch 3. The gap between the impeller and the pump cover is too long |
1Replace with new impeller 2Replace Motor 3 Reduce gaps |
|
Bearing overheating |
1Insufficient or too much lubricating oil 2 The pump shaft and the Motor shaft are not concentric 3 bearing damage 4. Bearing quality does not match |
1 Lubricating oil should cover 30-40% of the seal cavity 2Adjust to make the pump shaft and Motor shaft concentric 3Replace with new shaft 4. Reduce noise bearings |
|
Severe vibration |
1. The pump shaft and motor shaft are not concentric. 2 Pump shaft bent |
1Adjust to make the pump shaft and Motor shaft concentric 2 Re-change the axis |
|
seal leakage |
1Insufficient spring pressure 2 The moving or stationary ring end is corroded, worn or scratched 3. Corrosion and deformation of dynamic ring seal ring 4. Foreign matter or medium crystallization affects the main movement of the moving ring. |
1Adjust the spring compression or replace the spring 2Repair or replace the moving or static ring 3Replace the ring seal 4. Remove foreign matter or crystallization of media |
|
Motor overheating |
1. The specific gravity of the liquid or the temperature is too high 2. The mechanical seal spring is adjusted too tight. 3Voltage is too low 4. The assembly quality is poor, some parts are rubbing or the motor and pump shaft are not concentric. |
1 Increase Motor 2Re-adjust the spring compression amount 3Increase Voltage 4 Inspection of assembly quality and failure of assembly |
Selection Information Required
Please provide medium, concentration, flow, total head or pressure, temperature, viscosity or solids, voltage, frequency and installation method. DFIN Pump will confirm the suitable model and materials.
Catalog reference: authorized YZJ product data · Model JMZ
SELECTION SUPPORT
Application-based pump selection
Send the liquid, flow, head or pressure, temperature, solids, installation, power supply and destination for a verified recommendation.
Discuss this application