Reference image. Final construction follows the confirmed model and quotation.
Other Industrial Pumps
XBD(I) Fire Pressure-Stabilizing Pump
Model: XBD(I)
XBD(I) Fire Pressure-Stabilizing Pump is an industrial fire pump supported by DFIN Pump for model verification, material selection and technical review based on the actual medium and duty point.
TECHNICAL DATA
Specifications, performance and construction
Confirm the final operating point, materials, motor and connection standard before ordering.
Product Overview
XBD(I) Fire Pressure-Stabilizing Pump is an industrial fire pump selected for fire-water boosting and emergency water-supply systems. The final configuration should be verified against the actual liquid, duty point, temperature, installation and power supply.
Typical Applications
Fire-water boosting and emergency water-supply systems.
Design Features
- Reliable hydraulic performance
- Package and control options
- Project-based configuration
- Model and material selection supported by DFIN Pump engineers
Technical Performance Data
| Model |
Flow Q (L/S) |
pressure P (MPa) |
Speed n (r/min) |
Efficiency η (%) |
Power N (KW) |
RequiredNPSHr (NPSH)r (m) |
| XBD2.0/5-50L |
4 5 6 |
0.22 |
1450 |
48 52 50 |
2.2 | 3.2 |
| XBD3.0/5-50L |
4 5 6 |
0.33 |
1450 |
48 52 50 |
3 | 3.2 |
| XBD4.0/5-50L |
4 5 6 |
0.44 0.40 0.32 |
1450 |
48 52 50 |
4 | 3.2 |
| XBD5.0/5-50L |
4 5 6 |
0.55 0.50 0.40 |
1450 |
48 52 50 |
5.5 | 3.2 |
| XBD6.0/5-50L |
4 5 6 |
0.66 0.60 0.48 |
1450 |
48 52 50 |
5.5 | 3.2 |
| XBD7.0/5-50L |
4 5 6 |
0.77 0.70 0.56 |
1450 |
48 52 50 |
7.5 | 3.2 |
| XBD8.0/5-50L |
4 5 6 |
0.88 0.80 0.64 |
1450 |
48 52 50 |
7.5 | 3.2 |
| XBD9.0/5-50L |
4 5 6 |
0.99 0.90 0.72 |
1450 |
48 52 50 |
11 | 3.2 |
| XBD10.0/5-50L |
4 5 6 |
1.10 1.00 0.80 |
1450 |
48 52 50 |
11 | 3.2 |
| XBD2.8/10-65L |
8 |
0.32 0.28 0.24 |
1450 |
54 60 58 |
5.5 | 3.2 |
| XBD4.2/10-65L |
8 10 12 |
0.48 0.42 0.36 |
1450 |
54 60 58 |
7.5 | 3.2 |
| XBD5.6/10-65L |
8 10 12 |
0.64 0.56 0.48 |
1450 |
54 60 58 |
11 | 3.2 |
| XBD7.0/10-65L |
8 10 12 |
0.80 0.70 0.60 |
1450 |
54 60 58 |
15 | 3.2 |
| XBD8.4/10-65L |
8 10 12 |
0.96 0.84 0.72 |
1450 |
54 60 58 |
15 | 3.2 |
| XBD9.8/10-65L |
8 10 12 |
1.12 0.98 0.84 |
1450 |
54 60 58 |
18.5 | 3.2 |
| XBD11.2/10-65L |
8 10 12 |
1.28 1.12 0.96 |
1450 |
54 60 58 |
22 | 3.2 |
| XBD12.6/10-65L |
8 10 12 |
1.44 1.26 1.08 |
1450 |
54 60 58 |
22 | 3.2 |
| XBD14.0/10-65L |
8 10 12 |
1.60 1.40 1.20 |
1450 |
54 60 58 |
30 | 3.2 |
| XBD3.8/15-80L |
12 15 18 |
0.40 0.38 0.36 |
1450 |
62 70 66 |
11 | 3.5 |
| XBD5.7/15-80L |
12 15 18 |
0.60 0.57 0.54 |
1450 |
62 70 66 |
15 | 3.5 |
| XBD7.6/15-80L |
12 15 18 |
0.80 0.76 0.72 |
1450 |
62 70 66 |
22 | 3.5 |
| XBD9.5/15-80L |
12 15 18 |
1.00 0.95 0.90 |
1450 |
62 70 66 |
30 | 3.5 |
| XBD11.4/15-80L |
12 15 18 |
1.20 1.14 1.08 |
1450 |
62 70 66 |
30 | 3.5 |
| XBD13.3/15-80L |
12 15 18 |
1.40 1.33 1.26 |
1450 |
62 70 66 |
37 | 3.5 |
| XBD15.2/15-80L |
12 15 18 |
1.60 1.52 1.44 |
1450 |
62 70 66 |
45 | 3.5 |
| XBD17.1/15-80L |
12 15 18 |
1.80 1.71 1.62 |
1450 |
62 70 66 |
45 | 3.5 |
| XBD19.0/15-80L |
12 15 18 |
2.00 1.90 1.80 |
1450 |
62 70 66 |
55 | 3.5 |
| XBD3.8/25-100L |
15 25 32 |
0.42 0.38 0.34 |
1450 |
65 72 70 |
18.5 | 3.5 |
| XBD5.7/25-100L |
15 25 32 |
0.63 0.57 0.54 |
1450 |
65 72 70 |
30 | 3.5 |
| XBD7.6/25-100L |
15 25 32 |
0.84 0.76 0.68 |
1450 |
65 72 70 |
37 | 3.5 |
| XBD9.5/25-100L |
15 25 32 |
1.05 0.95 0.85 |
1450 |
65 72 70 |
45 | 3.5 |
| XBD11.4/25-100L |
15 25 32 |
1.26 1.14 1.02 |
1450 |
65 72 70 |
55 | 3.5 |
| XBD13.3/25-100L |
15 25 32 |
1.47 1.33 1.19 |
1450 |
65 72 70 |
75 | 3.5 |
| XBD15.2/25-100L |
15 25 32 |
1.68 1.52 1.36 |
1450 |
65 72 70 |
75 | 3.5 |
| XBD17.1/25-100L |
15 25 32 |
1.89 1.71 1.53 |
1450 |
65 72 70 |
90 | 3.5 |
| XBD19.0/25-100L |
15 25 32 |
2.10 1.90 1.70 |
1450 |
65 72 70 |
90 | 3.5 |
| XBD4.0/40-150L |
30 40 50 |
0.44 0.40 0.36 |
1450 |
75 80 77 |
30 | 3.5 |
| XBD6.0/40-150L |
30 40 50 |
0.66 0.60 0.54 |
1450 |
75 80 77 |
37 | 3.5 |
| XBD8.0/40-150L |
30 40 50 |
0.88 0.80 0.72 |
1450 |
75 80 77 |
45 | 3.5 |
| XBD10.0/40-150L |
30 40 50 |
1.10 1.00 0.90 |
1450 |
75 80 77 |
55 | 3.5 |
| XBD12.0/40-150L |
30 40 50 |
1.32 1.20 1.08 |
1450 |
75 80 77 |
75 | 3.5 |
| XBD14.0/40-150L |
30 40 50 |
1.54 1.40 1.26 |
1450 |
75 80 77 |
75 | 3.5 |
| XBD16.0/40-150L |
30 40 50 |
1.76 1.60 1.44 |
1450 |
75 80 77 |
90 | 3.5 |
| XBD5.0/45-150L |
32 45 55 |
0.54 0.50 0.44 |
1450 |
72 76 73 |
37 | 4.0 |
| XBD7.5/45-150L |
32 45 55 |
0.87 0.75 0.66 |
1450 |
72 76 73 |
55 | 4.0 |
| XBD10.0/45-150L |
32 45 55 |
1.08 1.00 0.8 |
1450 |
72 76 73 |
75 | 4.0 |
| XBD12.5/45-150L |
32 45 55 |
1.35 1.25 1.10 |
1450 |
72 76 73 |
90 | 4.0 |
| XBD15.0/45-150L |
32 45 55 |
1.62 1.50 1.32 |
1450 |
72 76 73 |
110 | 4.0 |
| XBD17.5/45-150L |
32 45 55 |
1.89 1.75 1.54 |
1450 |
72 76 73 |
132 | 4.0 |
| XBD20.0/45-150L |
32 45 55 |
2.16 2.00 1.76 |
1450 |
72 76 73 |
132 | 4.0 |
| XBD22.5/45-150L |
32 45 55 |
2.43 2.25 1.98 |
1450 |
72 76 73 |
160 | 4.0 |
| XBD6.0/75-200L |
50 75 90 |
0.66 0.60 0.54 |
1450 |
72 84 86 |
90 | 4.5 |
| XBD9.0/75-200L |
50 75 90 |
0.99 0.90 0.81 |
1450 |
72 84 86 |
110 | 4.5 |
| XBD12.0/75-200L |
50 75 90 |
1.32 1.20 1.08 |
1450 |
72 84 86 |
132 | 4.5 |
| XBD15.0/75-200L |
50 75 90 |
1.65 1.50 1.35 |
1450 |
72 84 86 |
160 | 4.5 |
| XBD18.0/75-200L |
50 75 90 |
1.98 1.80 1.62 |
1450 |
72 84 86 |
200 | 4.5 |
| XBD4.0/80-200L |
60 80 100 |
0.45 0.40 0.36 |
1450 |
70 79 77 |
55 | 5.0 |
| XBD6.0/80-200L |
60 80 100 |
0.68 0.60 0.54 |
1450 |
70 79 77 |
75 | 5.0 |
| XBD8.0/80-200L |
60 80 100 |
0.90 0.80 0.72 |
1450 |
70 79 77 |
110 | 5.0 |
| XBD10.0/80-200L |
60 80 100 |
1.12 1.00 0.90 |
1450 |
70 79 77 |
132 | 5.0 |
| XBD12.0/80-200L |
60 80 100 |
1.35 1.20 1.08 |
1450 |
70 79 77 |
160 | 5.0 |
| XBD14.0/80-200L |
60 80 100 |
1.58 1.40 1.26 |
1450 |
70 79 77 |
160 | 5.0 |
| XBD16.0/80-200L |
60 80 100 |
1.80 1.60 1.44S |
1450 |
70 79 77 |
200 | 5.0 |
Selection Information Required
Please provide medium, concentration, flow, total head or pressure, temperature, viscosity or solids, voltage, frequency and installation method. DFIN Pump will confirm the suitable model and materials.
Catalog reference: authorized YZJ product data · Model XBD(I)
SELECTION SUPPORT
Application-based pump selection
Send the liquid, flow, head or pressure, temperature, solids, installation, power supply and destination for a verified recommendation.
Discuss this application