Pump selection & global supply support+86 151 2119 9987 · dfin88@dfinsewagepump.com
CYZ-A Explosion-Proof Self-Priming Oil Pump

Reference image. Final construction follows the confirmed model and quotation.

Self-Priming Pumps

CYZ-A Explosion-Proof Self-Priming Oil Pump

Model: CYZ-A

CYZ-A Explosion-Proof Self-Priming Oil Pump is designed for fuel, lubricating oil and general petroleum-product transfer. DFIN Pump provides model verification, material selection and technical support based on the actual duty point.

TECHNICAL DATA

Specifications, performance and construction

Confirm the final operating point, materials, motor and connection standard before ordering.

Product Overview

CYZ-A Explosion-Proof Self-Priming Oil Pump is an industrial oil transfer pump selected for fuel, lubricating oil and general petroleum-product transfer. The final configuration should be verified against the actual liquid, duty point, temperature, installation and power supply.

Typical Applications

Fuel, lubricating oil and general petroleum-product transfer.

Design Features

  • Steady delivery
  • Compact construction
  • Multiple drive and seal options
  • Model and material selection supported by DFIN Pump engineers

Extracted Operating Data

  • mm :3.2-500m3/h :12-80m :1450/2900r/min :-20-80℃ : 、 :
  • :25-300mm :3.2-500m3/h :12-80m :1450/2900r/min

Values are reference data from the authorized source catalog. Confirm the selected model before ordering.

Technical Performance Data

Model

Motor Power
(kw)

Speed
(r/min)

Port Size
(mm)

Flow
(m 3 /h)

Head
(m)

Self-sniff height
(m)

25CYZ-A-20

1.1

2900

25

3.2

20

6

25CYZ-A-20

1.5

2900

25

3.2

32

6

32CYZ-A-20

3

2900

32

3.2

50

6

40CYZ-A-20

1.5

2900

40

6.3

20

5

40CYZ-A-32

2.2

2900

40

6.3

32

5

40CYZ-A-40

4

2900

40

10

40

5

40CYZ-A-50

4

2900

40

6.3

50

5

50CYZ-A-12

1.5

2900

50

12.5

12

5

50CYZ-A-20

2.2

2900

50

15

20

5

50CYZ-A-30

3

2900

50

12.5

30

5

50CYZ-A-35

4

2900

50

12.5

35

5

50CYZ-A-40

4

2900

50

10

40

5

50CYZ-A-50

5.5

2900

50

12.5

50

5

50CYZ-A-60

7.5

2900

50

12.5

60

5

50CYZ-A-75

11

2900

50

15

75

5

65CYZ-A-15

3

2900

65

30

15

4

65CYZ-A-32

5.5

2900

65

25

32

5

65CYZ-A-50

7.5

2900

65

25

50

5

65CYZ-A-70

15

2900

65

25

70

5

80CYZ-A-13

3

2900

80

35

13

3.5

80CYZ-A-17

4

2900

80

43

17

3.5

80CYZ-A-22

5.5

2900

80

40

22

3.5

80CYZ-A-25

7.5

2900

80

50

25

4

80CYZ-A-32

7.5

2900

80

50

32

4

80CYZ-A-40

11

2900

80

50

40

4

80CYZ-A-55

18.5

2900

80

60

55

4.5

80CYZ-A-70

22

2900

80

60

70

4.5

100CYZ-A-20

7.5

2900

100

80

20

3.5

100CYZ-A-25

11

2900

100

100

25

4.5

100CYZ-A-32

15

2900

100

100

32

4.5

100CYZ-A-40

18.5

2900

100

100

40

4.5

100CYZ-A-50

22

2900

100

100

50

4.5

100CYZ-A-65

30

2900

100

100

65

4.5

100CYZ-A-75

30

2900

100

100

75

4.5

150CYZ-A-20

18.5

1450

150

180

20

4.5

150CYZ-A-30

30

1450

150

170

30

4.5

150CYZ-A-45

37

2900

150

160

45

4.5

150CYZ-A-55

45

2900

150

160

80

4.5

150CYZ-A-65

55

2900

150

170

65

4.5

150CYZ-A-80

55

2900

150

160

80

4.5

200CYZ-A-32

90

1450

200

400

32

4.5

250CYZ-A-50

90

1450

250

400

50

4.5

300CYZ-A-50

110

1450

300

500

50

4.5

Form of failure

Causes

Troubleshooting

Self-suction oils are not pumped.

1. There is no liquid storage or insufficient liquid storage in the pump casing.
2. Air leakage in suction pipeline
3.Speed ​​is too low
4.Suction Lift is too high or suction pipe is too long
5. Mechanical seal leakage is too large
6. The gas in the suction line cannot be discharged from the Outlet.

1.Add enough reservoir fluid
2. Check and eliminate air leakage
3.Adjust Speed
4. Lower the Suction Lift or shorten the suction line
5. Repair or replace
6. Let it drain out

The self-suction pump noise and vibration are high

1. Unstable feet
2. The pump shaft is bent
3. Cavitation phenomenon
4. Bearing wear is serious
5. Miscellaneous items in and out of the pipeline
6. The main shafts of the pump and the motor are not concentric

1. Reinforcement
2. Replace or correct
3.Adjust working conditions
4. Replacement
5. Remove debris
6.Adjust coaxiality

There's not enough fuel to pump.

1. The impeller flow channel and suction pipe are blocked
2. The impeller or impeller seal is severely worn
3. Insufficient power or too low speed

1. Remove blockages
2. Replace the mouth ring
3.Add enough Power and adjust to rated Speed

Self-suction pump axle Power
It's too much.

1.Flow is too large
2.Speed ​​is too high
3. The pump shaft is bent or the impeller is stuck
4. The flow passage in the pump is blocked or stuck

1. Increase outlet pressure
2. Reduce appropriately
3. Replace or correct
4. Queue blockage

Selection Information Required

Please provide medium, concentration, flow, total head or pressure, temperature, viscosity or solids, voltage, frequency and installation method. DFIN Pump will confirm the suitable model and materials.

Catalog reference: authorized YZJ product data · Model CYZ-A

SELECTION SUPPORT

Application-based pump selection

Send the liquid, flow, head or pressure, temperature, solids, installation, power supply and destination for a verified recommendation.

Discuss this application
NEED SELECTION SUPPORT?

Send us your duty point. Our engineers will recommend a matched pump.

Talk to an engineer