Pump selection & global supply support+86 151 2119 9987 · dfin88@dfinsewagepump.com
G Stepless Variable-Speed Screw Pump

Reference image. Final construction follows the confirmed model and quotation.

Screw Pumps

G Stepless Variable-Speed Screw Pump

Model: G

G Stepless Variable-Speed Screw Pump is designed for viscous liquids, sludge, food, paper, chemical and process transfer. DFIN Pump provides model verification, material selection and technical support based on the actual duty point.

TECHNICAL DATA

Specifications, performance and construction

Confirm the final operating point, materials, motor and connection standard before ordering.

Product Overview

G Stepless Variable-Speed Screw Pump is an industrial screw pump selected for viscous liquids, sludge, food, paper, chemical and process transfer. The final configuration should be verified against the actual liquid, duty point, temperature, installation and power supply.

Typical Applications

Viscous liquids, sludge, food, paper, chemical and process transfer.

Design Features

  • Low-pulsation delivery
  • Good suction capability
  • Speed-proportional flow
  • Model and material selection supported by DFIN Pump engineers

Technical Performance Data

Model Flow
(m3/h)
pressure
(Mpa)
allow
High RPM
(r/min)
Motor
Power
(kw)
Necessary steam
Erosion allowance
(m)

Inlet method
orchid path
(mm)

Outlet method
orchid path
(mm)
Allowed
Diameter
(mm)
fiber allowed
dimension length
(mm)
G20-1 0.8 0.6 960 0.75 4 25 25 1.5 25
G20-2 1.2 1.5
G25-1 2 0.6 960 1.5 32 25 2 30
G25-2 1.2 2.2
G30-1 5 0.6 960 2.2 50 40 2.5 35
G30-2 1.2 3
G35-1 8 0.6 960 3 65 50 3 40
G35-2 1.2 4
G40-1 12 0.6 960 4 80 65 3.8 45
G40-2 1.2 5.5
G50-1 20 0.6 960 5.5 4.5 100 80 5 50
G50-2 1.2 7.5
G60-1 30 0.6 720 11 5 125 100 6 60
G60-2 1.2 15
G70-1 45 0.6 720 11 150 125 8 70
G70-2 1.2 18.5
G85-1 65 0.6 630 15 150 150 10 80
G85-2 1.2 30
G105-1 100 0.6 500 30 200 200 15 110
G105-2 1.2 55
G135-1 150 0.6 400 45 250 250 20 150
G135-2 1.2 90
Model Pressure 0.3Mpa Pressure 0.6Mpa Adjustable number of revolutions
Number of revolutions
(r/min)
Flow
(m3/h)
electric motor
Power
(kw)
Number of revolutions
(r/min)
Flow
(m3/h)
electric motor
Power
(kw)
Number of revolutions
(r/min)
Flow
(m3/h)
electric motor
Power
(kw)
G20-1 960 0.96 0.75-6 level 960 0.8 0.75-6 level 125~1250 0.1~1.5 1.1
720 0.8 0.55-8 level 720 0.5 0.75-8 level
510 0.4 0.55-4 level/gearbox 510 0.3 0.75-4 level/gearbox
G25-1 960 2.4 0.75-6 level 960 2 Level 1.5-6 125~1250 0.1~3 1.5
720 1.5 0.55-8 level 720 1.27 Level 1.1-8
510 1.08 0.55-4 level/gearbox 510 0.9 1.1-4 stage/gearbox
G30-1 960 3.6 Level 1.5-6 960 3 Level 2.2-6 125~1250 0.2~4 2.2
720 2.28 Level 1.1-8 720 1.9 Level 1.5-8
510 1.63 1.1-4 stage/gearbox 510 1.35 1.5-4 stage/gearbox
G35-1 720 4.8 Level 2.2-8 720 4.04 Level 3-8 125~890 0.3~5 3
510 3.36 1.5-4 stage/gearbox 510 2.8 2.2-4 stage/gearbox
380 1.92 1.1-4 stage/gearbox 380 1.60 1.5-4 stage/gearbox
G40-1 510 6.8 2.2-4 stage/gearbox 510 5.6 Level 3-4/Gearbox 125~890 0.3~10 4
380 5.1 1.5-4 stage/gearbox 380 4 2.2-4 stage/gearbox
252 2.65 1.1-6 stage/gearbox 252 2.2 1.5-6 stage/gearbox
G50-1 510 13.8 4-4 stage/gearbox 510 11.5 5.5-4 stage/gearbox 80~750 1~18 5.5
380 10.2 4-4 stage/gearbox 380 7.5 5.5-4 stage/gearbox
252 5.6 Level 3-6/Gearbox 252 4.4 5.5-6 stage/gearbox
G60-1 510 20.8 7.5-4 stage/gearbox 510 16 11-4 level/gearbox 63~630 1~20 11
380 15.6 7.5-4 stage/gearbox 380 12 11-4 level/gearbox
252 7.8 5.5-6 stage/gearbox 252 6 7.5-6 stage/gearbox
G70-1 510 26 11-4 level/gearbox 510 20 11-4 level/gearbox 56~560 1~22 11
380 17 7.5-4 stage/gearbox 380 13 11-4 level/gearbox
252 9.1 7.5-6 stage/gearbox 252 7 7.5-6 stage/gearbox
G85-1 380 32 11-4 level/gearbox 380 25 15-4 stage/gearbox 37~370 2~24 15
252 21 7.5-6 stage/gearbox 252 16 Level 11-6/Gearbox
189 11 5.5-8 stage/gearbox 189 8 Level 11-8/Gearbox
G105-1 380 80 15-4 stage/gearbox 380 65 22-4 stage/gearbox 29~290 3~50 22
252 44 15-6 level/gearbox 252 34 22-6 stage/gearbox
189 29 Level 11-8/Gearbox 189 22 Level 15-8/Gearbox
G135-1 380 132 37-4 stage/gearbox 380 120 45-4 stage/gearbox 18~180 3~56 45
252 95 Level 30-6/ gearbox 252 80 Level 37-6/ gearbox
189 65 18.5-6 / gearbox 189 53 Level 30-8/ gearbox
Model Pressure 0.8Mpa Pressure 1.2Mpa Adjustable number of revolutions
Number of revolutions
(r/min)
Flow
(m3/h)
electric motor
Power
(kw)
Number of revolutions
(r/min)
Flow
(m3/h)
electric motor
Power
(kw)
Number of revolutions
(r/min)
Flow
(m3/h)
electric motor
Power
(kw)
G20-2 960 0.96 Level 1.5-6 960 0.8 Level 1.5-6 125~1250 0.1~1.5 1.5
720 0.8 Level 1.1-8 720 0.5 Level 1.5-8
510 0.4 1.1-4 stage/gearbox 510 0.3 1.1-4 stage/gearbox
G25-2 960 2.4 Level 1.5-6 960 2 Level 2.2-6 125~1250 0.1~3 2.2
720 1.5 Level 1.1-8 720 1.27 Level 1.5-8
510 1.08 1.1-4 stage/gearbox 510 0.9 1.5-4 stage/gearbox
G30-2 960 3.6 Level 3-6 960 3 Level 3-6 125~1250 0.2~4 3
720 2.28 Level 1.5-8 720 1.9 Level 2.2-8
510 1.63 1.5-4 stage/gearbox 510 1.35 2.2-4 stage/gearbox
G35-2 720 4.8 Level 3-8 720 4.04 Level 4-8 125~890 0.3~5 4
510 3.36 2.2-4 stage/gearbox 510 2.8 Level 3-4/Gearbox
380 1.92 1.5-4 stage/gearbox 380 1.60 2.2-4 stage/gearbox
G40-2 510 6.8 4-4 stage/gearbox 510 5.6 5.5-4 stage/gearbox 125~890 0.3~10 5.5
380 5.1 Level 3-4/Gearbox 380 4 4-4 stage/gearbox
252 2.65 2.2-6 Class/ gearbox 252 2.2 Level 3-6/Gearbox
G50-2 510 13.8 5.5-4 stage/gearbox 510 11.5 7.5-4 stage/gearbox 80~750 1~18 7.5
380 10.2 4-4 stage/gearbox 380 7.5 5.5-4 stage/gearbox
252 5.6 Level 3-6/Gearbox 252 4.4 5.5-6 stage/gearbox
G60-2 510 20.8 15-4 stage/gearbox 510 16 15-4 stage/gearbox 63~630 1~20 15
380 15.6 11-4 level/gearbox 380 12 15-4 stage/gearbox
252 7.8 7.5-6 stage/gearbox 252 6 Level 11-6/Gearbox
G70-2 510 26 15-4 stage/gearbox 510 20 18.5-4 level/ gearbox 56~560 1~22 18.5
380 17 11-4 level/gearbox 380 13 15-4 stage/gearbox
252 9.1 Level 11-6/Gearbox 252 7 Level 11-6/Gearbox
G85-2 380 32 18.5-4 level/ gearbox 380 25 22-4 stage/gearbox 37~370 2~24 22
252 21 15-6 level/gearbox 252 16 18.5-6 / gearbox
189 11 Level 15-8/Gearbox 189 8 Level 15-8/Gearbox
G105-2 380 80 30-4 level/ gearbox 380 65 37-4 stage/gearbox 29~290 3~50 37
252 44 Level 30-6/ gearbox 252 34 Level 30-6/ gearbox
189 29 Level 22-8/ gearbox 189 22 Level 22-8/ gearbox
G135-2 380 132 55-4 level/ gearbox 380 120 75-4 level/ gearbox 18~180 3~56 75
252 95 Level 55-6/ gearbox 252 80 75-6 level/ gearbox
189 65 Level 37-8/ gearbox 189 53 45-8 level/ gearbox
Type of pump Flow
(m3/h)
Work Pressure (Mpa) Transfers (r/min) Gear deceleration with Speed Motor (kw)
G30-2  ~1 1.2 30~300 YCT160/4A-2.2
G35-2  ~2 1.2 30~300 YCT160/4A-2.2
G40-2  ~3 1.2 30~280 YCT160/4A-3
G50-1  ~4.5 0.6 28~280 YCT180/4A-4
G50-2  ~4.5 1.2 28~280 YCT200/4A-5.5
G60-1  ~6.5 0.6 25~250 YCT200/4A-5.5
G60-2  ~6.5 1.2 25~250 YCT200/4B-7.5
G70-1  ~8 0.6 25~250 YCT200/4B-7.5
G85-1  ~12.5 0.6 18~180 YCT225/4A-11
G105-1  ~20 0.6 14~140 YCT225/4B-15
G135-1  ~35 0.6 10~100 YCT250/4B-22
Rubber characteristics Ting Jiu Rubber NBR Chlorbutyl rubber CR Fluorine rubber PPM Epdm.
High temperature tolerance +120°C +110°C +200°C +150°C
Perseverance Yu Good. Yu Good.
Age-resilient Good. Good. Yu Yu
Ozone-resistant No way. Yu Yu Yu
Steam tolerance Good. No way. Yu Yu
Flammability Good. Yu Yu Yu
Adaptation of rubber Epdm. Fluorine rubber PPM Chlorbutyl rubber CR Ting Jiu Rubber NBR
Water (septic) Good. Good. Good. Good.
Vegetable oil General Good. General Good.
Mineral oil No way. Good. General Good.
ammonia General No way. No way. Good.
Aromatic solvents No way. Good. No way. No way.
Enriched alkalin Good. No way. Good. Good.
Concentrated nitric acid No way. General No way. No way.
- Iceacetic acid. No way. Good. No way. Good.
dilute sulfuric acid Good. Good. No way. Good.
Concentrated sulfuric acid General Good. No way. No way.
dilute hydrochloric acid Good. Good. Good. Good.
Concentrated hydrochloric acid Good. Good. No way. Good.
Hot water. Good. No way. No way. General
gasoline No way. Good. General Good.
Toluene No way. Good. No way. No way.
Dimethylbenzene No way. Good. No way. No way.
ethanol Good. Good. Good. General
kerosene No way. Good. Good. Good.
Diesel No way. Good. No way. Good.
Hydrocarbons chloride No way. General No way. No way.
Quantico-type material Good. No way. No way. No way.
Intoxicants Good. Good. Good. Good.
Waste-containing materials Good. No way. No way. No way.
Ether-like materials Good. No way. No way. No way.
Mud Good. General General Good.
Phosphate Good. General Good. General
Sodium carbonate Good. No way. Good. Good.
Salud Good. General General General
Benzene 100 No way. Good. No way. No way.
acetone Good. No way. No way. No way.
Nasty oil. Good. Good. Good. Good.
carbon disulfide No way. Good. No way. No way.
Fault Reason Troubleshooting
One, pump is not activated. a. New pump turn, tweaked.
b. Voltage, low current
c. High-plugging media
a. Helping to turn circles with tools and manpower
b. Inspection, adjustment
c. Diluent fluids
Two, no fluid. a. The rotation is not in the right direction
b. Inhalation pipelines are problematic
c. High-plugging media
d. Turn, fixed damage or damage to moving parts
e. Pump internal guidance jamming
a. Reorientation
b. Check for leaks and open the Outlet valves
c. Diluent fluids
d. Check replacements
c. Excludes replacement
Three, Flow can't reach. a. Pipe leaks
b. Valves are not fully open or partially blocked
c. Speed's too low.
d. Turn, fixed wear
a. Inspection of repair pipes
b. Open all valves, remove jamming
c. Adjustments to Sped
d. Replacement of other damage
Pressure is not reaching 4. a. Rotation, fixed wear a. Replacement shifts, fixed
Five, Motor overheat. A. Motor malfunction
b. Outlet overstretched, Motor overloaded
c. Stable burn or glued to rotor
a. Checking Motor, Voltage, current, frequency.
b. Check Head, get to the Outlet valve, and clear the block.
c. Replacement of damage
Six, Flow pressure is dropping sharply. a. Sudden congestion or leaking of pipes
b. Bad wear and tear
c. Sudden change in the viscosity of the liquid
d. Voltage suddenly falling
Individual exclusions by reference
7 and axle seals are full of leaks. a. Molotovated soft fillings
b. Mechanical seal damage
a. Tightening or replacing fillings
b. Repair or replacement

Selection Information Required

Please provide medium, concentration, flow, total head or pressure, temperature, viscosity or solids, voltage, frequency and installation method. DFIN Pump will confirm the suitable model and materials.

Catalog reference: authorized YZJ product data · Model G

SELECTION SUPPORT

Application-based pump selection

Send the liquid, flow, head or pressure, temperature, solids, installation, power supply and destination for a verified recommendation.

Discuss this application
NEED SELECTION SUPPORT?

Send us your duty point. Our engineers will recommend a matched pump.

Talk to an engineer