Pump selection & global supply support+86 151 2119 9987 · dfin88@dfinsewagepump.com
SKA Series Vacuum Pump

Reference image. Final construction follows the confirmed model and quotation.

Vacuum Pumps

SKA Series Vacuum Pump

Model: SKA

SKA Series Vacuum Pump is designed for vacuum generation, gas removal and process evacuation. DFIN Pump provides model verification, material selection and technical support based on the actual duty point.

TECHNICAL DATA

Specifications, performance and construction

Confirm the final operating point, materials, motor and connection standard before ordering.

Product Overview

SKA Series Vacuum Pump is an industrial vacuum pump selected for vacuum generation, gas removal and process evacuation. The final configuration should be verified against the actual liquid, duty point, temperature, installation and power supply.

Typical Applications

Vacuum generation, gas removal and process evacuation.

Design Features

  • Stable vacuum performance
  • Industrial-duty construction
  • Application-specific material options
  • Model and material selection supported by DFIN Pump engineers

Technical Performance Data

Curve Numbering Model Air mass (m3/min) Maximum vacuum (MPa) Motor Power
(kw)
Pumped (R.P.m.) Work fluid Flow (L/min) Noise
(A)
Weight
(kg)
60V SKA20.60 0.45 0.097 0.81 2880 2 62 37
61V SKA20.61 0.86 0.097 1.45 2880 2 65 41
70V SKA20.70 1.33 0.097 2.35 2850 2.5 66 66
71V SKA20.71 1.83 0.097 3.85 2860 4.2 72 85
110V SKA5110 2.75 0.097 4 1450 6.7 63 120
111V SKA5111 3.83 0.097 5.5 1450 8.3 68 150
121V SKA5121 4.66 0.097 7.5 1450 10 69 210
131V SKA5131 6.66 0.097 11 1430 15 73 280
161V SKA5161 8.33 0.097 15 970 20 74 390
110V SKA6110 2.75 0.097 4 1450 6.7 63  
111V SKA6111 3.83 0.097 5.5 1450 8.3 68  
121V SKA6121 4.66 0.097 7.5 1450 10 69  
131V SKA6131 6.66 0.097 11 1430 15 73  
161V SKA6161 8.33 0.097 15 970 20 74  
Model Curve Numbering A B B1 E H1 H2 H3 H4 H6 M P2 P3
SKA2-060 60V 455 186 140 100 90 118 126 195 37.5 244 250 180
SKA2-061 61V 476 186 140 100 90 118 195 195 37.5 263 250 180
SKA2-070 70V 545 223 160 140 222 100 128 222 33 280 270 203
SKA2-071 71V 566 223 234 190 140 112 140 234 45 309 300 225
Model Curve Numbering R S2 W1 W2 W3 d N3.0 N4.2 N8.7
SKA2-060 60V 217 φ10 110 25.5 21 G1 G3/877 G1/4" G3/8"
SKA2-061 61V 236 φ10 110 25.5 21 G1 G3/877 G1/4" G3/8"
SKA2-070 70V 252 φ12 110 33 27 G11/2" G3/877 G1/4" G3/8"
SKA2-071 71V 278 φ12 110 33 27 G11/2" G3/877 G1/4" G3/8"
Model Curve Numbering A B B1 B2 C1 C2 H1 H2 H3 H4 H5 H6 H7 K L
SKA5110-OKC 101V 637 325 255 190 41 26 140 156 202 361 328 38 57 342 130
SKA5111-0KC 111V 672 325 265 216 38 26 150 166 212 371 363 48 68 348 130
SKA5121-OKC 121V 771 347 265 216 36 26 150 167 217 385 363 39 60 430 147
SKA5131-OKC 131V 852 377 300 254 35 30 175 194 249 427 435 53 76 477.5 147
SKA5161-0KC 161V 1044 479 370 389 52 30 210 225 303 521 485 51 80 570 201
Model Curve Numbering F N S1 S92 T d1 d2 d3 d4 d5
SKA5110-0KC… 101V 464 92 φ12X23 φ12 340 19 160 123 97 52
SKA5111-OKC… 111V 500 92 φ12X23 φ12 340 19 160 123 97 52
SKA5121-0KC… 121V 584 97 φ12X23 φ12 382 19 182 142 113 66.5
SKA5131-OKC… 131V 658,5 103 φ12X23 φ14 382 19 182 142 113 66.5
SKA5161-OKC… 161V 808 138 φ15×27 φ14 450 22 200 156 130 80
Model Curve Numbering W1 W2 W3 "d(N1.0,N2.0)" N3.0 N4.2 N8.7
SKA5110-OKC… 101V 180 52 27 "DN50/2" G3/4." G3/8." G3/8."
SKA5111-OKC… 111V 180 52 27 "DN50/2" G3/4 "(24 long) G3/8." G3/8."
SKA5121-OKC… 121V 200 57 29 "DN65/21/2" G3/4." G3/8." G3/8."
SKA5131-OKC… 131V 200 62.5 32 "DN65/21/2" G3/4." G3/8 "(25 long) G3/8."
SKA5161-OKC… 161V 250 81 41 "DN80/3" G3/4." G3/8." G3/8."

Selection Information Required

Please provide medium, concentration, flow, total head or pressure, temperature, viscosity or solids, voltage, frequency and installation method. DFIN Pump will confirm the suitable model and materials.

Catalog reference: authorized YZJ product data · Model SKA

SELECTION SUPPORT

Application-based pump selection

Send the liquid, flow, head or pressure, temperature, solids, installation, power supply and destination for a verified recommendation.

Discuss this application
NEED SELECTION SUPPORT?

Send us your duty point. Our engineers will recommend a matched pump.

Talk to an engineer