Reference image. Final construction follows the confirmed model and quotation.
Magnetic Pumps
ZCQ Self-Priming Magnetic Drive Pump
Model: ZCQ
ZCQ Self-Priming Magnetic Drive Pump is designed for chemical transfer and applications requiring improved liquid containment. DFIN Pump provides model verification, material selection and technical support based on the actual duty point.
TECHNICAL DATA
Specifications, performance and construction
Confirm the final operating point, materials, motor and connection standard before ordering.
Product Overview
ZCQ Self-Priming Magnetic Drive Pump is an industrial magnetic pump selected for chemical transfer and applications requiring improved liquid containment. The final configuration should be verified against the actual liquid, duty point, temperature, installation and power supply.
Typical Applications
Chemical transfer and applications requiring improved liquid containment.
Design Features
- Sealless magnetic coupling
- Corrosion-resistant material options
- Compact and low-maintenance construction
- Model and material selection supported by DFIN Pump engineers
Technical Performance Data
| Model | Flow (m3/h) | Head (m) | Motor Power (kw) | Suction Lift (m) |
| 20-12-110 | 3 | 12 | 0.37 | 4 |
| 25-20-115 | 6.6 | 15 | 1.1 | 4 |
| 32-25-115 | 6.6 | 15 | 1.1 | 4 |
| 32-25-145 | 6.6 | 25 | 1.1 | 4 |
| 40-32-132 | 10.8 | 20 | 2.2 | 4 |
| 40-32-160 | 12 | 32 | 4 | 4 |
| 50-40-145 | 14.4 | 25 | 4 | 4 |
| 50-40-160 | 13.2 | 32 | 4 | 4 |
| 65-50-145 | 16.8 | 25 | 5.5 | 4 |
| 65-50-160 | 27 | 32 | 7.5 | 4 |
| 80-65-160 | 51 | 32 | 15 | 4 |
| 80-50-200 | 51 | 50 | 22 | 4 |
| 80-50-250 | 51 | 80 | 37 | 4 |
| 100-80-160 | 100 | 32 | 22 | 4 |
| 100-65-200 | 100 | 50 | 37 | 4 |
| 100-65-250 | 100 | 80 | 55 | 4 |
| Model | A | B1 | B2 | B3 | h | H | H1 | H2 | L | L1 | L2 | m-φd3 |
| ZCQ25-20-115 | 132 | 170 | 216 | 240 | 80 | 290 | 70 | 400 | 410 | 150 | 300 | 4-φ11.5 |
| ZCQ32-25-115 | 132 | 170 | 216 | 240 | 80 | 290 | 70 | 400 | 410 | 150 | 300 | 4-φ11.5 |
| ZCQ32-25-145 | 132 | 170 | 216 | 240 | 80 | 290 | 70 | 400 | 410 | 150 | 300 | 4-φ11.5 |
| ZCQ40-32-132 | 140 | 170 | 216 | 240 | 90 | 290 | 70 | 400 | 640 | 175 | 360 | 4-φ11.5 |
| ZCQ40-32-160 | 145 | 235 | 290 | 330 | 112 | 315 | 80 | 415 | 705 | 175 | 400 | 4-φ13.5 |
| ZCQ50-32-125 | 145 | 235 | 290 | 330 | 112 | 350 | 80 | 480 | 790 | 180 | 420 | 4-φ13.5 |
| ZCQ50-32-160 | 150 | 235 | 290 | 330 | 112 | 350 | 80 | 480 | 790 | 180 | 420 | 4-φ13.5 |
| ZCQ50-32-200 | 150 | 270 | 316 | 350 | 132 | 420 | 82 | 615 | 870 | 210 | 500 | 4-φ13.5 |
| ZCQ65-50-125 | 180 | 270 | 316 | 350 | 132 | 400 | 82 | 590 | 830 | 210 | 450 | 4-φ13.5 |
| ZCQ65-50-160 | 180 | 270 | 316 | 350 | 132 | 400 | 82 | 590 | 870 | 210 | 500 | 4-φ13.5 |
| ZCQ65-40-200 | 180 | 340 | 400 | 440 | 160 | 446 | 96 | 650 | 1040 | 230 | 610 | 4-φ18.5 |
| ZCQ80-65-125 | 200 | 270 | 316 | 350 | 132 | 446 | 82 | 630 | 960 | 230 | 520 | 4-φ13.5 |
| ZCQ80-65-160 | 200 | 340 | 400 | 440 | 160 | 446 | 96 | 630 | 1060 | 230 | 610 | 4-φ18.5 |
| ZCQ80-50-200 | 200 | 340 | 400 | 440 | 180 | 470 | 96 | 680 | 1090 | 230 | 610 | 4-φ18.5 |
| ZCQ80-50-250 | 200 | 375 | 460 | 510 | 220 | 510 | 100 | 760 | 1250 | 280 | 700 | 4-φ28 |
| ZCQ100-80-160 | 240 | 340 | 400 | 440 | 180 | 465 | 96 | 650 | 1090 | 250 | 700 | 4-φ24 |
| ZCQ100-65-200 | 240 | 375 | 460 | 510 | 220 | 510 | 100 | 760 | 1250 | 280 | 700 | 4-φ28 |
| ZCQ100-65-250 | 240 | 435 | 520 | 570 | 280 | 620 | 120 | 860 | 1410 | 300 | 880 | 4-φ28 |
| Form of failure | Causes | Troubleshooting |
| Self-suction magnetic force doesn't pump water. | & nbsp;a, water pumps reverse | changing the Motor connection |
| b, leak in the pipe | Erosion Elimination | |
| c, too little pump cavity | Increase water storage | |
| d, Voltage too high, slider on startup | Correct Voltage | |
| e, Saction Lift too high | Reduce sand installation position | |
| f, valves not opened | fix or change valves | |
| Self-suction magnetic pump Flow is inadequate | a, inhaler tube too small or silt | Switching to pipe |
| & nbsp;b, leaf rotation tunnel block | Cleaning Wheels | |
| c, Head Too High | Opens the water valve | |
| & nbsp;d, Sped not enough | Recovered | |
| Self-suction magnetic pump Head too low | a, Flow is too big | Turn off the water valve |
| & nbsp;b, Sped too low | Recovered | |
| Self-suction magnetic pump noise is too high. | a, axle severe wear | replacement pump axle |
| b, axial wear | replace axle | |
| & nbsp;c, drive magnetic steel cups and quarantine | Dismantling pump head reassembly | |
| & nbsp;d, Seal rings and leaf wheel grinding | replace stopring rings, sealing rings | |
| Self-sniffing magnetic pump leak | & nbsp; Type O seals damaged | replace O seal |
Selection Information Required
Please provide medium, concentration, flow, total head or pressure, temperature, viscosity or solids, voltage, frequency and installation method. DFIN Pump will confirm the suitable model and materials.
Catalog reference: authorized YZJ product data · Model ZCQ
SELECTION SUPPORT
Application-based pump selection
Send the liquid, flow, head or pressure, temperature, solids, installation, power supply and destination for a verified recommendation.
Discuss this application