Pump selection & global supply support+86 151 2119 9987 · dfin88@dfinsewagepump.com
MT-HTP Stainless Steel High-Temperature Magnetic Drive Pump

Reference image. Final construction follows the confirmed model and quotation.

Magnetic Pumps

MT-HTP Stainless Steel High-Temperature Magnetic Drive Pump

Model: MT-HTP

MT-HTP Stainless Steel High-Temperature Magnetic Drive Pump is designed for chemical transfer and applications requiring improved liquid containment. DFIN Pump provides model verification, material selection and technical support based on the actual duty point.

TECHNICAL DATA

Specifications, performance and construction

Confirm the final operating point, materials, motor and connection standard before ordering.

Product Overview

MT-HTP Stainless Steel High-Temperature Magnetic Drive Pump is an industrial magnetic pump selected for chemical transfer and applications requiring improved liquid containment. The final configuration should be verified against the actual liquid, duty point, temperature, installation and power supply.

Typical Applications

Chemical transfer and applications requiring improved liquid containment.

Design Features

  • Sealless magnetic coupling
  • Corrosion-resistant material options
  • Compact and low-maintenance construction
  • Model and material selection supported by DFIN Pump engineers

Extracted Operating Data

  • :3.2~100m3/h :15~80m :-45~350℃ :32~100mm : 2850~2900
  • :3.2~100m3/h :15~80m :-45~350℃ :32~100mm : 2850~2900r/min :1.1~55k

Values are reference data from the authorized source catalog. Confirm the selected model before ordering.

Technical Performance Data

No. Part name Material No. Part name Material
1 Pump body Stainless SteelZGCr18Ni9 8 Bearing body Stainless SteelZG1Cr18Ni9
2 buckle Stainless Steel1Cr18Ni9Ti 9 Bearing Carbon graphite M120P
3 impeller Stainless SteelZG1Cr18Ni9 10 Isolation sleeve Stainless Steel1Cr18Ni9Ti
4 thrust ring Carbide YG8 11 Internal magnet assembly Samarium cobalt magnet assembly
5 sealing ring PTFE F4 12 External magnet assembly Samarium cobalt magnet assembly
6 cooling device Stainless Steel Assemblies 13 Cooling connection frame Casting HT200
7 pump shaft Stainless Steel1Cr18Ni9Ti      
model Port Size(mm) Flow(m3/h) Head

(m)

Motor Power(kW) Voltage

 (V)

Material
Inlet Outlet
MT-HTP32-25-115 32 25 6.6 15 1.1 380 No
rust
steel
MT-HTP32-20-125 32 20 3.2 20 1.1 380
MT-HTP 32-20-160 32 20 3.2 32 1.5 380
MT-HTP 40-25-125 40 25 6.3 20 2.2 380
MT-HTP 40-25-160 40 25 6.3 32 3 380
MT-HTP 40-25-200 40 25 6.3 50 5.5 380
MT-HTP 50-32-125 50 32 12.5 20 3 380
MT-HTP 50-32-160 50 32 12.5 32 4 380
MT-HTP 50-32-200 50 32 12.5 50 7.5 380
MT-HTP 50-32-250 50 32 12.5 80 18.5 380
MT-HTP 65-50-125 65 50 25 20 4 380
MT-HTP 65-50-160 65 50 25 32 7.5 380
MT-HTP 65-40-200 65 40 25 50 15 380
MT-HTP 65-40-250 65 40 25 80 18.5 380
MT-HTP 80-65-125 80 65 50 20 7.5 380
MT-HTP 80-65-160 80 65 50 32 15 380
MT-HTP 80-50-200 80 50 50 50 18.5 380
MT-HTP 80-50-250 80 50 50 80 37 380
MT-HTP 100-80-125 100 80 100 20 15 380
MT-HTP 100-80-160 100 80 100 32 18.5 380
MT-HTP 100-65-200 100 65 100 50 37 380
MT-HTP 100-65-250 100 65 100 80 55 380
Note: Each Model can be equipped with an explosion-proof Motor
Model A B C D E F G L H1 H2 H3 φ
MT-HTP32-20-125 140 270 270 250 290 67.5 145 898 60 175 290 12
MT-HTP32-20-160 140 273 270 250 290 67.5 155 918 60 175 335 12
MT-HTP40-25-105 140 270 270 250 290 65 155 918 60 175 250 12
MT-HTP40-25-125 140 270 270 250 290 65 155 918 60 175 290 12
MT-HTP40-25-160 170 157 580 350 390 80 190 1342 80 217 380 19
MT-HTP40-25-200 170 157 645 380 420 80 210 1497 80 250 430 19
MT-HTP50-32-160 170 162 580 350 390 80 190 1342 80 217 380 19
MT-HTP50-32-200 170 157 645 380 420 80 210 1537 80 250 430 19
MT-HTP50-32-250 275 265 840 490 560 100 255 1927 90 280 505 24
MT-HTP65-50-160 170 157 645 380 420 120 210 1537 80 235 455 19
MT-HTP65-40-200 275 165 840 490 560 100 210 1893 90 260 440 19
MT-HTP65-40-250 275 265 840 490 560 100 285 1927 90 270 505 24
MT-HTP80-65-160 275 265 840 490 560 100 255 1893 90 260 440 24
MT-HTP80-50-200 275 265 840 490 560 100 255 1927 90 260 460 24
MT-HTP80-50-250 275 258 870 490 560 125 285 1998 90 280 525 24
MT-HTP100-80-125 275 258 840 490 560 100 255 1893 90 250 430 19
MT-HTP100-80-160 275 275 840 490 560 100 255 1927 90 260 460 24
MT-HTP100-65-200 300 300 930 550 610 100 305 2140 100 280 505 24
MT-HTP100-65-250 300 300 1080 550 610 125 335 2300 100 300 650 28
Fault phenomena Reason analysis Troubleshooting
The pump does not produce water 1. Water pump reverses

2. Air leakage in water inlet pipe

3. Insufficient water storage in the pump chamber

4. The Voltage is too high and the coupling slips during startup.

5. Suction Lift is too high

6. The valve is not open

1. Adjust the Motor rotation direction

2. Prevent air leakage

3. Increase water storage capacity

4. Adjust Voltage

5. Lower the pump installation position

6. Correct or change valves

Insufficient Flow 1. Suction pipe diameter size or blockage

2. Impeller flow passage blocked

3. Head is too high

4. Speed ​​is not enough

1. Replace or clean the water inlet pipe

2. Clean the impeller

3. Open the water outlet valve.

4. Restore rated Speed

Head too low 1. Flow is too large

2. Speed ​​is too low

1. Close the water outlet valve

2. Restore rated Speed

The bath sound is too loud 1. The pump shaft is severely worn

2. Bearings severely worn

3. The outer magnet or inner magnet is in contact with the isolation sleeve

4. Grinding of sealing ring and impeller

5. Wear of rolling bearings in the cooling box

1. Replace the pump shaft

2. Replace bearings

3. Disassemble the pump head and reassemble it

4. Replace thrust ring and sealing ring

5. Replace rolling bearings

Leakage 1. The O-ring is damaged 1. Replace the O-ring

Selection Information Required

Please provide medium, concentration, flow, total head or pressure, temperature, viscosity or solids, voltage, frequency and installation method. DFIN Pump will confirm the suitable model and materials.

Catalog reference: authorized YZJ product data · Model MT-HTP

SELECTION SUPPORT

Application-based pump selection

Send the liquid, flow, head or pressure, temperature, solids, installation, power supply and destination for a verified recommendation.

Discuss this application
NEED SELECTION SUPPORT?

Send us your duty point. Our engineers will recommend a matched pump.

Talk to an engineer