Pump selection & global supply support+86 151 2119 9987 · dfin88@dfinsewagepump.com
ISW Series Horizontal Centrifugal Pump/ Horizontal Clean-Water Pump

Reference image. Final construction follows the confirmed model and quotation.

Centrifugal & Pipeline Pumps

ISW Series Horizontal Centrifugal Pump/ Horizontal Clean-Water Pump

Model: ISW

ISW Series Horizontal Centrifugal Pump/ Horizontal Clean-Water Pump is designed for clean-water transfer, pressure boosting, circulation and general industrial service. DFIN Pump provides model verification, material selection and technical support based on the actual duty point.

TECHNICAL DATA

Specifications, performance and construction

Confirm the final operating point, materials, motor and connection standard before ordering.

Product Overview

ISW Series Horizontal Centrifugal Pump/ Horizontal Clean-Water Pump is an industrial centrifugal pump selected for clean-water transfer, pressure boosting, circulation and general industrial service. The final configuration should be verified against the actual liquid, duty point, temperature, installation and power supply.

Typical Applications

Clean-water transfer, pressure boosting, circulation and general industrial service.

Design Features

  • Compact hydraulic design
  • Stable flow with low vibration
  • Multiple materials and motor options
  • Model and material selection supported by DFIN Pump engineers

Extracted Operating Data

  • 1、 ≤1.0Mpa, ≤1.6Mpa, + ≤ 1.6Mpa、 2.5Mpa,
  • 1.6Mpa
  • 2、 <40℃, <95%
  • 3、 0.1%, <0.2mm.

Values are reference data from the authorized source catalog. Confirm the selected model before ordering.

Technical Performance Data

1

Suction chamber: designed using excellent hydraulic models.

2

Impeller: designed using excellent hydraulic models, highly efficient and energy-saving.

3

Pump body: designed using excellent hydraulic models.

4

Remove the pressure plug: Install a pressure gauge and vacuum gauge to monitor the normal and efficient operation of the pump.

5

Bleed Plug: Ensures proper maintenance of the pump.

6

Mechanical seal: Made of Stainless Steel, carbide, fluororubber and other materials, durable consumer goods wear, no leakage, long operating life.

7

Pump cover:

8

Pump shaft: The Motor lengthened shaft ensures the concentricity of the shaft and ensures smooth operation without noise or vibration.

9

Water retaining ring: prevents water from entering the Motor due to seal leakage.

10

Y series motors: directly connected to the water pump to transmit power, some of them adopt Shanghai famous brand Motor.

Model

Port Size

Flow

Head

Efficiency

Speed

Motor Power

RequiredNPSHr

mm

m3/h

L/S

m

%

r/min

KW

(NPSH)r

15-80

15

1.1
1.5
2.0

0.3
0.42
0.55

8.5
8
7

26
34
34

2800

0.18

2.3

20-110

20

1.8
2.5
3.3

0.5
0.69
0.91

16
15
13.5

25
34
35

2800

0.37

2.3

20-160

20

1.8
2.5
3.3

0.5
0.69
0.91

33
32
30

19
25
23

2900

0.75

2.3

25-110

25

2.8
4
5.2

0.78
1.11
1.44

16
15
13.5

34
42
41

2900

0.55

2.3

25-125

25

2.8
4
5.2

0.78
1.11
1.44

20.6
20
18

28
36
35

2900

0.75

2.3

25-125A

25

2.5
3.6
4.6

0.69
1.0
1.28

17
16
14.4

35

2900

0.55

2.3

25-160

25

2.8
4
5.2

0.78
1.11
1.44

33
32
30

24
32
33

2900

1.5

2.3

25-160A

25

2.6
3.7
4.9

0.12
1.03
1.36

29
28
26

31

2900

1.1

2.3

Model

Port Size

Flow

Head

Efficiency

Speed

Motor Power

RequiredNPSHr

mm

m3/h

L/S

m

%

r/min

KW

(NPSH)r

32-100(I)

32

4.4
6.3
8.3

1.22
1.75
2.32

13.2
12.5
11.3

48
54
53

2900

0.75

2.0

32-125

32

3.5
5
6.5

0.97
0.39
1.8

22
20
18

40
44
42

2900

0.75

2.3

32-125A

32

3.1
4.5
5.8

0.86
1.25
1.61

17.6
16
14.4

43

2900

0.55

2.3

32-160(I)

32

4.4
6.3
8.3

1.22
1.75
2.32

33.2
32
30.2

34
40
42

2900

2.2

2.0

32-200(I)

32

4.4
6.3
8.3

1.22
1.75
2.32

50.5
50
48

26
33
35

2900

4

2.0

32-200A

32

2.8
4
5.2

0.78
1.11
1.44

44.6
44
42.7

34
40
42

2900

2.2

2.0

Model

Port Size

Flow

Head

Efficiency

Speed

Motor Power

RequiredNPSHr

mm

m3/h

L/S

m

%

r/min

KW

(NPSH)r

40-100

40

4.4
6.3
8.3

1.22
1.75
2.31

13.2
12.5
11.3

48
54
53

2900

0.55

2.3

40-100A

40

3.9
5.6
7.4

1.08
1.56
2.06

10.6
10
9

52

2900

0.37

2.3

40-125

40

4.4
6.3
8.3

1.22
1.75
2.31

21
20
18

41
46
43

2900

1.1

2.3

40-125A

40

3.9
5.6
7.4

1.08
1.56
2.06

17.6
16
14.4

40
45
41

2900

0.75

2.3

40-160

40

4.4
6.3
8.3

1.22
1.75
2.31

33
32
30

35
40
40

2900

2.2

2.3

40-160A

40

4.1
5.9
7.8

1.14
1.64
2.17

29
28
26.3

34
39
39

2900

1.5

2.3

40-160B

40

3.8
5.5
7.2

1.06
1.53
2.0

25.5
24
22.5

34
38
37

2900

1.1

2.3

40-200

40

4.4
6.3
8.3

1.22
1.75
2.31

51
50
48

26
33
32

2900

4

2.3

40-200A

40

4.1
5.9
7.8

1.14
1.64
2.17

45
44
42

26
31
30

2900

3

2.3

40-200B

40

3.7
5.3
7.0

1.03
1.47
1.94

38
36
34.5

29

2900

2.2

2.3

40-250

40

4.4
6.3
8.3

1.22
1.75
2.31

82
80
74

24
28
28

2900

7.5

2.3

40-250A

40

4.1
5.9
7.8

1.14
1.64
2.17

72
70
65

24
28
27

2900

5.5

2.3

40-250B

40

3.8
5.5
7.0

1.06
1.53
1.94

61.5
60
56

23
27
26

2900

4

2.3

Model

Port Size

Flow

Head

Efficiency

Speed

Motor Power

RequiredNPSHr

mm

m3/h

L/S

m

%

r/min

KW

(NPSH)r

40-100(I)

40

8.8
12.5
16.3

2.44
3.47
4.53

13.2
12.5
11.3

55
62
60

2900

1.1

2.3

40-100(I)A

40

8
11
14.5

2.22
3.05
4.03

10.6
10
9

60

2900

0.75

2.3

40-125(I)

40

8.8
12.5
16.3

2.44
3.47
4.53

21.2
20
17.8

49
58
57

2900

1.5

2.3

40-125(I)A

40

8
11
14.5

2.22
3.05
4.03

17
16
14

57

2900

1.1

2.3

40-160(I)

40

8.8
12.5
16.3

2.44
3.47
4.53

33
32
30

45
52
51

2900

3

2.3

40-160(I)A

40

8.2
11.7
15.2

2.28
3.25
4.22

29
28
26

44
51
50

2900

2.2

2.3

40-160(I)B

40

7.3
10.4
13.5

2.38
2.89
3.75

23
22
20.5

50

2900

1.5

2.3

40-200(I)

40

8.8
12.5
16.3

2.44
3.47
4.53

51.2
50
48

38
46
46

2900

5.5

2.3

40-200(I)A

40

8.3
11.7
15.3

2.31
3.25
4.25

45.0
44
42

37
45
45

2900

4

2.3

40-200(I)B

40

7.5
10.6
13.8

2.08
2.94
3.83

37
36
34

44

2900

3

2.3

40-250(I)

40

8.8
12.5
16.3

2.44
3.47
4.53

81.2
80
77.5

31
38
40

2900

11

2.3

40-250(I)A

40

8.2
11.6
15.2

2.28
3.22
4.22

71.0
70
68

38

2900

7.5

2.3

40-250(I)B

40

7.6
10.8
14

2.11
3.0
3.89

61.4
60
58

37

2900

7.5

2.3

40-250(I)C

40

7.1
10.0
13.1

1.97
2.78
3.64

53.2
52
50.4

36

2900

5.5

2.3

Model

Port Size

Flow

Head

Efficiency

Speed

Motor Power

RequiredNPSHr

mm

m3/h

L/S

m

%

r/min

KW

(NPSH)r

50-100

50

8.8
12.5
16.3

2.44
3.47
4.53

13.6
12.5
11.3

55
62
60

2900

1.1

2.3

50-100A

50

8
11
14.5

2.22
3.05
4.03

11
10
9

60

2900

0.75

2.3

50-125

50

8.8
12.5
16.3

2.44
3.47
4.53

21.5
20
17.8

49
58
57

2900

1.5

2.3

50-125A

50

8
11
14.5

2.22
3.05
4.03

17
16
14

57

2900

1.1

2.3

50-160

50

8.8
12.5
16.3

2.44
3.47
4.53

33
32
30

45
52
51

2900

3

2.3

50-160A

50

8.2
11.7
15.2

2.28
3.25
4.22

29
28
26

44
51
50

2900

2.2

2.3

50-160B

50

7.3
10.4
13.5

2.38
2.89
3.75

23
22
20.5

50

2900

1.5

2.3

50-200

50

8.8
12.5
16.3

2.44
3.47
4.53

52
50
48

38
46
46

2900

5.5

2.3

50-200A

50

8.3
11.7
15.3

2.31
3.25
4.25

45.8
44
42

37
45
45

2900

4

2.3

50-200B

50

7.5
10.6
13.8

2.08
2.94
3.83

37
36
34

44

2900

3

2.3

50-250

50

8.8
12.5
16.3

2.44
3.47
4.53

82
80
77.5

29
38
40

2900

11

2.3

50-250A

50

8.2
11.6
15.2

2.28
3.22
4.22

71.5
70
68

38

2900

7.5

2.3

50-250B

50

7.6
10.8
14

2.11
3.0
3.89

61.4
60
58

37

2900

7.5

2.3

50-250C

50

7.1
10.0
13.1

1.97
2.78
3.64

53.2
52
50.4

36

2900

5.5

2.3

Model

Port Size

Flow

Head

Efficiency

Speed

Motor Power

RequiredNPSHr

mm

m3/h

L/S

m

%

r/min

KW

(NPSH)r

50-100(I)

50

17.5
25
32.5

4.86
6.94
9.03

13.7
12.5
10.5

67
69
69

2900

1.5

2.5

50-100(I)A

50

15.6
22.3
29

4.3
6.19
8.1

11
10
8.4

65
67
68

2900

1.1

2.5

50-125(I)

50

17.5
25
32.5

4.86
6.94
9.03

21.5
20
18

60
68
67

2900

3

2.5

50-125(I)A

50

15.6
22.3
29

4.33
6.19
8.1

17
16
13.6

58
66
65

2900

2.2

2.5

50-160(I)

50

17.5
25
32.5

4.68
6.94
9.03

34.4
32
27.5

54
63
60

2900

4

2.5

50-160(I)A

50

16.4
23.4
30.4

4.56
6.5
8.44

30
28
24

54
62
59

2900

4

2.5

50-160(I)B

50

15.0
21.6
28

4.17
6.0
7.78

26
24
20.6

58

2900

3

2.5

50-200(I)

50

17.5
25
32.5

4.86
6.94
9.03

52.7
50
45.5

49
58
59

2900

7.5

2.5

50-200(I)A

50

16.4
23.5
30.5

4.56
6.53
8.47

46.4
44
40

48
57
58

2900

7.5

2.5

50-200(I)B

50

15.2
21.8
28.3

4.22
6.06
7.86

40
38
34.5

55

2900

5.5

2.5

50-250(I)

50

17.5
25
32.5

4.86
6.94
9.03

82
80
76.5

39
50
52

2900

15

2.5

50-250(I)A

50

16.4
23.4
30.5

4.56
6.5
8.47

71.5
70
67

39
50
52

2900

11

2.5

50-250(I)B

50

15
21.6
28

4.17
6.0
7.78

61
60
57.4

38
49
54

2900

11

2.5

50-315(I)

50

17.5
25
32.5

4.86
6.94
9.03

128
125
122

30
40
44

2900

30

2.5

50-315(I)A

50

16.6
23.7
31

4.61
6.58
8.6

115
113
110

30
40
44

2900

22

2.5

50-315(I)B

50

15.7
22.5
29.2

4.36
6.25
8.0

103
101
98

39

2900

18.5

2.5

50-315(I)C

50

14.4
20.6
26.8

4.0
5.72
7.44

86
85
83

38

2900

15

2.5

Model

Port Size

Flow

Head

Efficiency

Speed

Motor Power

RequiredNPSHr

m3/h

L/S

m

%

r/min

KW

(NPSH)r

65-100

65

17.5
25
32.5

4.86
6.94
9.03

13.7
12.5
10.5

67
69
69

2900

1.5

2.5

65-100A

65

15.6
22.3
29

4.3
6.19
8.1

11
10
8.4

65
67
68

2900

1.1

2.5

65-125

65

17.5
25
32.5

4.86
6.94
9.03

21.5
20
18

60
68
67

2900

3

2.5

65-125A

65

15.6
22.3
29

4.33
6.19
8.1

17
16
14.4

58
66
65

2900

2.2

2.5

65-160

65

17.5
25
32.5

4.86
6.94
9.03

34.4
32
27.5

54
63
60

2900

4

2.5

65-160A

65

16.4
23.4
30.4

4.56
6.5
8.44

30
28
24

54
62
59

2900

4

2.5

65-160B

65

15.0
21.6
28

4.17
6.0
7.78

26
24
20.6

58

2900

3

2.5

65-200

65

17.5
25
32.5

4.86
6.94
9.03

52.7
50
45.5

49
58
59

2900

7.5

2.5

65-200A

65

16.4
23.5
30.5

4.56
6.53
8.47

46.4
44
40

48
57
58

2900

7.5

2.5

65-200B

65

15.2
21.8
28.3

4.22
6.06
7.86

40
38
34.5

55

2900

5.5

2.5

65-250

65

17.5
25
32.5

4.86
6.94
9.03

82
80
76.5

39
50
52

2900

15

2.5

65-250A

65

16.4
23.4
30.5

4.56
6.5
8.47

71.5
70
67

39
50
52

2900

11

2.5

65-250B

65

15
21.6
28

4.17
6.0
7.78

61
60
57.4

38
49
54

2900

11

2.5

65-315

65

17.5
25
32.5

4.86
6.94
9.03

127
125
122

32
40
44

2900

30

2.5

65-315A

65

16.6
23.7
31

4.61
6.58
8.6

115
113
110

32
40
44

2900

22

2.5

65-315B

65

15.7
22.5
29.2

4.36
6.25
8.0

103
101
98

39

2900

18.5

2.5

65-315C

65

14.4
20.6
26.8

4.0
5.72
7.44

86
85
83

38

2900

15

2.5

Model

Port Size

Flow

Head

Efficiency

Speed

Motor Power

RequiredNPSHr

mm

m3/h

L/S

m

%

r/min

KW

(NPSH)r

65-100(I)

65

35
50
65

9.72
13.9
18.1

13.8
12.5
10

67
73
70

2900

3

3.0

65-100(I)A

65

31.3
44.7
58

8.7
12.4
16.1

11
10
8

66
72
69

2900

2.2

3.0

65-125(I)

65

35
50
65

9.72
13.9
18.1

22
20
17

67
72.5
70

2900

5.5

3.0

65-125(I)A

65

31.3
44.7
58

8.7
12.5
16.1

17.5
16
13.6

66
71
69

2900

4

3.0

65-160(I)

65

35
50
65

9.72
13.9
18.1

35
32
28

63
71
70

2900

7.5

3.0

65-160(I)A

65

32.7
46.7
61

9.1
13.0
16.9

30.6
28
24

62
70
69

2900

7.5

3.0

65-160(I)B

65

30.3
43.3
56.3

8.4
12.0
15.6

26
24
21

69

2900

5.5

3.0

65-200(I)

65

35
50
65

9.72
13.9
18.1

53.5
50
46

55
67
68

2900

15

3.0

65-200(I)A

65

32.8
47
61

9.1
13.1
16.9

47
44
40

54
66
67

2900

11

3.0

65-200(I)B

65

30.5
43.5
56.6

8.5
12.1
15.7

40.6
38
33.4

65

2900

7.5

3.0

65-250(I)

65

35
50
65

9.72
13.9
18.1

83
80
72

52
59
60

2900

22

3.0

65-250(I)A

65

32.5
46.7
61

9.0
13.0
16.9

73
70
63

52
59
60

2900

18.5

3.0

65-250(I)B

65

30
43.3
56

8.3
12.0
15.6

62
60
54

58

2900

15

3.0

65-315(I)

65

35
50
65

9.72
13.9
18.1

128
125
121

44
54
57

2900

37

3.0

65-315(I)A

65

32.5
46.5
60.5

9.0
12.9
16.8

112.6
110
106.4

43
54
57

2900

30

3.0

65-315(I)B

65

31
44.5
58

8.6
12.4
16.1

102.5
100
98

53

2900

30

3.0

65-315(I)C

65

29
41
53.6

8.1
11.4
14.9

87
85
83

51

2900

22

3.0

Model

Port Size

Flow

Head

Efficiency

Speed

Motor Power

RequiredNPSHr

mm

m3/h

L/S

m

%

r/min

KW

(NPSH)r

80-100

80

35
50
65

9.72
13.9
18.1

13.8
12.5
10

67
73
70

2900

3

3.0

80-100A

80

31.3
44.7
58

8.7
12.5
16.1

11
10
8

66
72
69

2900

2.2

3.0

80-125

80

35
50
65

9.72
13.9
18.1

22
20
17

67
72.5
70

2900

5.5

3.0

80-125A

80

31.3
45
58

8.7
12.5
16.1

17.5
16
13.6

66
71
69

2900

4

3.0

80-160

80

35
50
65

9.72
13.9
18.1

35
32
28

63
71
70

2900

7.5

3.0

80-160A

80

32.7
46.7
61

9.1
13.0
16.9

30.6
28
24

62
70
69

2900

7.5

3.0

80-160B

80

30.3
43.3
56.3

8.4
12.0
15.6

26
24
21

69

2900

5.5

3.0

80-200

80

35
50
65

9.72
13.9
18.1

53.5
50
46

55
67
68

2900

15

3.0

80-200A

80

32.8
47
61

9.1
13.1
16.9

47
44
40

54
66
67

2900

11

3.0

80-200B

80

30.5
43.5
56.6

8.5
12.1
15.7

40.6
38
33.4

65

2900

7.5

3.0

80-250

80

35
50
65

9.72
13.9
18.1

83
80
72

52
59
60

2900

22

3.0

80-250A

80

32.5
46.7
61

9.0
13.0
16.9

73
70
63

52
59
60

2900

18.5

3.0

80-250B

80

30
43.3
56

8.3
12.0
15.6

62
60
54

58

2900

15

3.0

80-315

80

35
50
65

9.72
13.9
18.1

128
125
122

43
54
57

2900

37

3.0

80-315A

80

32.5
46.5
60.5

9.0
12.9
16.8

112.6
110
107.4

43
54
57

2900

30

3.0

80-315B

80

31
44.5
58

8.6
12.4
16.1

102.5
100
98

53

2900

30

3.0

80-315C

80

29
41
53.6

8.1
11.4
14.9

98
85
83

51

2900

22

3.0

80-350

80

35
50
65

9.72
13.9
18.1

146
150
142

55
66
67

2900

55

3.0

80-350A

80

31
44.5
58

8.6
12.4
16.1

138.4
142
134.8

65

2900

45

3.0

80-350B

80

29
41
53.6

8.1
11.4
14.9

131.4
135
127.8

63

2900

37

3.0

Model

Port Size

Flow

Head

Efficiency

Speed

Motor Power

RequiredNPSHr

mm

m3/h

L/S

m

%

r/min

KW

(NPSH)r

80-100(I)

80

70
100
130

19.4
27.8
36.1

13.6
12.5
11

66
76
75

2900

5.5

4.5

80-100(I)A

80

62.6
89
116

17.4
24.7
32.2

11
10
8.8

64
74
74

2900

4

4.5

80-125(I)

80

70
100
130

19.4
27.8
36.1

23.5
20
14

70
76
65

2900

11

4.5

80-125(I)A

80

62.6
89
116

17.4
24.7
32.2

19
16
11

68
74
65

2900

7.5

4.5

80-160(I)

80

70
100
130

19.4
27.8
36.1

36.5
32
24

70
76
65

2900

15

4.5

80-160(I)A

80

65.4
93.5
121.6

18.2
26.0
33.8

32
28
21

68
74
67

2900

11

4.5

80-160(I)B

80

60.6
86.6
112.5

16.8
24.1
31.3

72
24
18

72

2900

11

4.5

80-200(I)

80

70
100
130

19.4
27.8
36.1

54
50
42

65
74
73

2900

22

4.0

80-200(I)A

80

65.4
93.5
121.6

18.2
26.0
33.8

47.5
44
37

64
73
72

2900

18.5

4.0

80-200(I)B

80

61
87
113

16.9
24.2
31.4

41
38
32

71

2900

15

4.0

80-250(I)

80

70
100
130

19.4
27.8
36.1

87
80
68

62
69
68

2900

37

4.0

80-250(I)A

80

65.4
93.5
121.6

18.2
26.0
33.8

76
70
59.5

61
68
67

2900

30

4.0

80-250(I)B

80

61
87
113

16.9
24.2
31.4

65
60
51

66

2900

30

4.0

80-315(I)

80

70
100
130

19.4
27.8
36.1

132
125
114

55
66
67

2900

75

4.0

80-315(I)A

80

66.5
95
123.6

18.5
26.4
34.3

119
113
103

55
66
67

2900

55

4.0

80-315(I)B

80

63
90
117

17.5
25
32.5

106.6
101
92

65

2900

45

4.0

80-315(I)C

80

58
82
107

16.1
22.8
29.7

90
85
76

63

2900

37

4.0

Model

Port Size

Flow

Head

Efficiency

Speed

Motor Power

RequiredNPSHr

mm

m3/h

L/S

m

%

r/min

KW

(NPSH)r

100-100

100

70
100
130

19.4
27.8
36.1

13.6
12.5
11

66
76
75

2900

5.5

4.5

100-100A

100

62.6
89
116

17.4
47
32.2

11
10
8.8

64
74
74

2900

4

4.5

100-125

100

70
100
130

19.4
27.8
36.1

23.5
20
14

70
76
65

2900

11

4.5

100-125A

100

62.6
89
116

17.4
24.7
32.2

19
16
11

68
74
63

2900

7.5

4.5

100-160

100

70
100
130

19.4
27.8
36.1

36.5
32
24

70
76
65

2900

15

4.5

100-160A

100

65.4
93.5
121.6

18.2
26.0
33.8

32
28
21

68
74
67

2900

11

4.5

100-160B

100

60.6
86.6
112.5

16.8
24.1
31.3

27
24
18

72

2900

11

4.5

100-200

100

70
100
130

19.4
27.8
36.1

54
50
42

65
74
73

2900

22

4.0

100-200A

100

65.4
93.5
121.6

18.2
26.0
33.8

47.5
44
37

64
73
72

2900

18.5

4.0

100-200B

100

61
87
113

16.9
24.2
31.4

41
38
32

71

2900

15

4.0

100-250

100

70
100
130

19.4
27.8
36.1

37
80
68

62
69
68

2900

37

4.0

100-250A

100

65.4
93.5
121.6

18.2
26.0
33.8

76
70
59.5

61
68
67

2900

30

4.0

100-250B

100

61
87
113

16.9
24.2
31.4

65
60
51

66

2900

30

4.0

100-315

100

70
100
130

19.4
27.8
36.1

132
125
114

55
66
67

2900

75

4.0

100-315A

100

66.5
95
123.6

18.5
26.4
34.3

119
113
103

65
66
67

2900

55

4.0

100-315B

100

63
90
117

17.5
25
32.5

106.6
101
92

65

2900

45

4.0

100-315C

100

58
82
107

16.1
22.8
29.7

90
85
76

63

2900

37

4.0

Model

Port Size

Flow

Head

Efficiency

Speed

Motor Power

RequiredNPSHr

mm

m3/h

L/S

m

%

r/min

KW

(NPSH)r

100-100(I)

100

96
160
192

26.7
44.4
53.3

14
12.5
10

64
73
70

2900

11

4.5

100-125(I)

100

96
160
192

26.7
44.4
53.3

24
20
14

62
74
69

2900

15

4.5

100-125(I)A

100

84
140
168

23.3
39
46.7

20
17
12

64
72
68

2900

11

4.5

100-160(I)

100

96
160
192

26.7
44.4
53.3

36
32
27

69
79
75

2900

22

5.6

100-160(I)A

100

84
140
168

23.3
39
46.7

32
28
23.5

66
76
72

2900

18.5

5.0

100-200(I)

100

96
160
192

26.7
44.4
53.3

53
50
45

69
79
78

2900

37

5.2

100-200(I)A

100

84
140
168

23.3
39
46.7

48
45
40

64
74
73

2900

30

4.5

100-200(I)B

100

60
100
120

16.7
27.8
33.3

43
40
36

72

2900

22

4.5

100-250(I)

100

96
160
192

26.7
44.4
53.3

83
80
72

65
77
74

2900

55

4.8

100-250(I)A

100

84
140
168

23.3
39
46.7

75
72
65

60
72
69

2900

45

4.5

100-250(I)B

100

60
100
120

16.7
27.8
33.3

68
65
58

70

2900

37

4.5

100-350

100

60
100
120

16.7
27.8
33.3

153.6
150
142

72
57
74

2900

90

4.0

100-350A

100

61
87
113

16.9
24.2
31.4

145.6
142
134

75

2900

75

4.0

100-350B

100

58
82
107

16.1
22.8
29.7

138.6
135
127

75

2900

55

4.0

Model

Port Size

Flow

Head

Efficiency

Speed

Motor Power

RequiredNPSHr

mm

m3/h

L/S

m

%

r/min

KW

(NPSH)r

125-100

125

96
160
192

26.7
44.4
53.3

13
12.5
12

82

2900

11

4.0

125-100A

125

86
143
172

23.9
39.7
47.8

10.4
10
9.6

77

2900

7.5

4.0

125-125

125

96
160
192

26.7
44.4
53.3

22.6
20
17

80

2900

15

4.0

125-125A

125

86
143
172

23.9
39.7
47.8

18
16
13.6

77

2900

11

4.0

125-160

125

96
160
192

26.7
44.4
53.3

36
32
28

78

2900

22

4.0

125-160A

125

90
150
180

25
41.7
50

31.5
28
24.5

76

2900

18.5

4.0

125-160B

125

83
138
166

21.7
38.3
46.1

27
24
21

73

2900

15

4.0

125-200

125

96
160
192

26.7
44.4
53.3

55
50
46

77

2900

37

5.5

125-200A

125

90
150
180

25
41.7
50

48.4
44
40.5

76

2900

30

5.5

125-200B

125

83
138
166

21.7
38.3
46.1

41.3
37.5
34.5

75

2900

22

5.5

125-250

125

96
160
192

26.7
44.4
53.3

87
80
73

75

2900

55

5.0

125-250A

125

90
150
180

25
41.7
50

76
70
84

74

2900

45

5.5

125-250B

125

83
138
166

21.7
38.3
46.1

65
60
55

73

2900

37

5.5

125-315

125

96
160
192

26.7
44.7
53.3

133
125
119

70

2900

90

5.0

125-315A

125

90
150
180

25
41.7
50

117
110
104.6

70

2900

75

5.0

125-315B

125

86
143
172

23.9
39.7
47.8

106.4
100
95.2

69

2900

75

5.0

125-315C

125

80.5
134
161

22.4
37.2
44.7

96
88
86

67

2900

55

5.0

Model

Port Size

Flow

Head

Efficiency

Speed

Motor Power

RequiredNPSHr

mm

m3/h

L/S

m

%

r/min

KW

(NPSH)r

150-125

150

96
160
192

26.7
44.4
53.3

22.6
24
17

66
76
76

2900

11

4.0

150-125A

150

90
150
180

25
41.7
50

18
16
13.6

77

2900

7.5

4.0

150-160

150

96
160
192

26.7
44.4
53.3

36
32
27

75

2900

22

4.0

150-160A

150

90
150
180

25
41.7
50

32
28
23.5

76

2900

18.5

4.0

150-160B

150

84
140
168

23.3
39
46.7

27
24
21

73

2900

15

4.0

150-200

150

140
200
260

38.9
55.6
72.2

13.8
12.5
10.6

68
78
78

1450

15

3.0

150-200A

150

125
176
232.5

34.7
49.7
64.6

11
10
8.5

66
76
76

1450

11

3.0

150-200B

150

84
140
168

23.3
39
46.7

41
38
34

75

2900

22

4.0

150-250

150

140
200
260

38.9
55.6
72.2

21.8
20
17

73
79
77

1450

18.5

3.0

150-250A

150

129
184.4
240

35.8
51.2
66.7

18.5
17
14.4

72
78
76

1450

15

3.0

150-250B

150

117
167
217.5

32.5
46.4
60.4

15.2
14
12

76

1450

11

3.0

150-315

150

140
200
260

38.9
55.6
72.2

33.8
32
28

70
78
73

1450

30

2.5

150-315A

150

131
187
243

36.4
51.9
67.5

29.5
28
24.5

69
77
77

1450

22

3.5

150-315B

150

121
173
225

33.5
48.1
62.5

25
24
21

76

1450

18.5

3.5

150-350

150

96
160
192

26.7
44.4
53.3

153.6
150
142.8

80

2900

110

5.5

150-350A

150

90
150
180

25
41.7
50

145.6
142
134.8

70

2900

90

5.2

150-350B

150

84
140
168

23.3
39
46.7

138.6
135
127.8

65
76
74

2900

75

5.5

150-400

150

140
200
260

38.9
55.6
72.2

53
50
44

68
75
71

1450

45

3.5

150-400A

150

131
187
243

36.4
51.9
67.5

46.6
44
38.3

67
74
70

1450

37

3.5

150-400B

150

122
174
226.5

33.9
48.3
62.9

40
38
33

73

1450

30

3.5

150-400C

150

112
160
208

31.1
44.4
57.8

34
32
28

71

1450

22

3.5

Model

Port Size

Flow

Head

Efficiency

Speed

Motor Power

RequiredNPSHr

mm

m3/h

L/S

m

%

r/min

KW

(NPSH)r

150-250(I)

150

120
200
240

33.3
55.6
66.7

87
80
72

65
76
74

2900

75

4.5

150-250(I)A

150

112
187
224

31.1
51.9
62.2

76
70
63

64
75
73

2900

55

4.5

150-250(I)B

150

104
173
208

28.9
48.1
57.8

65
60
54

63
74
72

2900

45

4.5

150-315(I)

150

120
200
240

33.3
55.6
66.7

133
125
120

58
73
75

2900

110

4.5

150-315(I)A

150

112
187
224

31.1
51.9
62.2

116
110
105

57
72
74

2900

90

4.5

150-315(I)B

150

104
173
208

28.9
48.1
57.8

100
95
91

55
70
72

2900

75

4.5

Model

Port Size

Flow

Head

Efficiency

Speed

Motor Power

RequiredNPSHr

mm

m3/h

L/S

m

%

r/min

KW

(NPSH)r

200-200

200

140
200
260

38.9
55.6
72.2

13.8
12.5
10.6

68
78
78

1450

15

3.0

200-200A

200

125
179
232.5

34.7
49.7
64.6

11
10
8.5

66
76
76

1450

11

3.0

200-250

200

140
200
260

21.8
20
17

21.8
20
17

73
79
77

1450

18.5

3.0

200-250A

200

129
184.4
240

18.5
17
14.4

18.5
17
14.4

72
78
76

1450

15

3.0

200-250B

200

117
167
217.5

15.2
14
12

15.2
14
12

76

1450

11

3.0

200-315

200

140
200
260

33.8
32
28

33.8
32
28

70
78
78

1450

30

3.5

200-315A

200

131
189
243

29.5
28
24.5

29.5
28
24.5

69
77
77

1450

22

3.5

200-315B

200

121
173
225

25
24
21

25
24
21

76

1450

18.5

3.5

200-400

200

140
200
260

53
50
44

53
50
44

68
75
71

1450

45

3.5

200-400A

200

131
187
243

46.6
44
38.3

46.6
44
38.3

67
74
70

1450

37

3.5

200-400B

200

122
174
226.5

40
38
33

40
38
33

73

1450

30

3.5

200-400C

200

112
160
208

34
32
28

34
32
28

71

1450

22

3.5

Model

Port Size

Flow

Head

Efficiency

Speed

Motor Power

RequiredNPSHr

mm

m3/h

L/S

m

%

r/min

KW

(NPSH)r

200-200(I)

200

280
400
520

77.8
111.1
144

13.4
12.5
10.5

70
80
79

1450

22

4.0

200-200(I)A

200

250
358
465

69.4
90.4
129.2

10.7
10
8.5

68
73
77

1450

18.5

4.0

200-250(I)

200

280
400
520

77.8
111.1
144

22.2
20
14

75
80
72

1450

30

4.0

200-250(I)A

200

250
358
465

69.4
99.4
129.2

18
16
11.2

73
78
70

1450

22

4.0

200-250(I)B

200

226
322
419

62.8
89.4
116.4

14.4
13
7.3

70
75
67

1450

18.5

4.0

200-315(I)

200

280
400
520

77.8
111.4
144

36
32
26

73
80
75

1450

55

4.0

200-315(I)A

200

262
374
486

72.8
103.9
135

31.5
28
23

72
79
74

1450

45

4.0

200-315(I)B

200

242
346
450

67.3
96.1
125

27
24
19.5

78

1450

37

4.0

200-400(I)

200

280
400
520

77.8
111.4
144

54.5
50
39

75
81
77

1450

75

4.0

200-400(I)A

200

262
374
486

72.8
103.9
135

48
44
34

80

1450

75

4.0

200-400(I)B

200

242
346
450

67.2
96.1
125

41.4
38
29.6

78

1450

55

5.0

200-400(I)C

200

224
320
416

62.2
88.9
115.6

34.9
32
25

76

1450

45

5.0

Model

Port Size

Flow

Head

Efficiency

Speed

Motor Power

RequiredNPSHr

mm

m3/h

L/S

m

%

r/min

KW

(NPSH)r

250-250

250

350
550
650

97.2
152.8
180.5

22
20
16

78
82
81

1450

45

5.0

250-250A

250

300
500
600

83.3
139
166.7

18.3
17
14

76
80
80

1450

37

5.0

250-235

250

300
500
600

83.3
139
166.7

14
12.5
11

73
78
70

1480

22

4.5

250-300

250

300
500
600

83.3
139
166.7

22
20
16

78

1480

37

4.5

250-315

250

350
550
650

97.2
152.8
180.5

34
32
28

76
80
79

1450

75

5.5

250-315A

250

300
500
600

83.3
139
166.7

29.5
28
24

74
78
77

1450

55

5.5

250-315B

250

260
450
520

72.2
125
144.4

25
24
20

70
74
72

1450

45

5.5

250-400

250

300
500
600

83.3
139
166.7

54.5
50
39

72

1480

90

4.5

Model

Port Size

Flow

Head

Efficiency

Speed

Motor Power

RequiredNPSHr

mm

m3/h

L/S

m

%

r/min

KW

(NPSH)r

300-235

300

480
720
900

133.3
200
250

20
18
15.5

77
81
74

970

55

5.0

300-235A

300

438
607
821

121.7
182.5
228.1

16.5
15
13

75
79
72

970

45

5.0

300-235B

300

400
600
750

111.1
167.0
208.3

14
12.5
11

73
77
70

970

37

5.0

300-300

300

480
720
900

133.3
200
250

31
28
25

77
81
77

970

75

5.0

300-300A

300

444
666
833

123.3
185
231.4

26.5
24
21.5

76
80
76

970

75

5.0

300-300B

300

415
623
779

115.3
173.1
261.4

23
21
18.5

79

970

55

5.0

300-380

300

480
720
900

133.3
200
250

48
44
34

84

970

132

5.0

300-380A

300

444
666
833

123.3
185
231.4

41.4
38
30

80

970

110

5.0

300-380B

300

409
614
767

113.6
170.6
213.1

35
32
25

78

970

90

5.0

300-235(I)

300

718
1080
1345

199.4
300
373.6

44.6
40
34.6

82

1450

160

5.5

300-235(I)A

300

642
965
1203

178.3
268.1
334.2

35.7
32
27.7

80

1450

132

5.5

1

Inlet ball valve

2

Flexible joint

3

Straight pipe

4

Outlet gate valve

5

pump

6

Base

7

cement base

1

Inlet ball valve

2

Flexible joint

3

Straight pipe

4

Outlet gate valve

5

pump

6

Base

7

JGD type shock absorber

8

cement base

Fault phenomena

Possible causes

Troubleshooting

1. The water pump does not discharge water

a. The inlet outlet valve is not opened, the inlet and outlet pipelines are blocked, and the impeller flow path is blocked.
b. The motor is running in the wrong direction and the motor is missing phase.
c. The suction pipe is leaking.
d. The pump is not filled with liquid and there is air in the pump chamber.

e. Inlet water supply is insufficient, Suction Lift is too high, and the bottom valve is leaking.

f. The pipeline resistance is too large.

a. Check and remove obstructions.
b. Adjust the direction of the Motor and tighten the Motor wiring.
c. Tighten each sealing surface to remove air.
d. Open the upper cover of the pump or open the exhaust valve to exhaust the
Air.
e. Shut down for inspection and adjustment (grid-connected water pipes
This phenomenon is prone to occur when using a Suction Lift. )
f. Reduce pipeline bends and reselect the pump.

2. Insufficient water pump flow

a On 1 first.
b. Pipes and impellers are partially blocked, scale is deposited, and valve opening is insufficient.
c. Voltage is low and Speed ​​does not meet the requirements.
d. Impeller wear.

a. Press 1 first. exclude.
b. Remove the obstruction first and readjust the valve opening.
c. Voltage stabilization
d. Replace the impeller

3. Power is too large

a. Use exceeding the rated flow
b. Suction Lift is too high
c. Pump bearing wear
d. Improper pump selection

a. Adjust Flow and close the valve
b. Lower the Suction Lift.
c. Replace the bearings.
d. Re-select the pump.

4. Noise and vibration

a. The pipeline support is unstable.
b. Liquid mixed with gas.
c. Cavitation occurs.
d. Bearing vibration.
e. Motor is overloaded and running hot.

a. Stabilize the pipeline.
b. Increase the suction pressure and exhaust.
c. Reduce the vacuum degree.
d. Replace the bearing.
e. To adjust, press 5.

5. Motor fever

a. Flow is too large and overloaded.
b. Bump.
c. Motor bearing is damaged.
d. Voltage is low.

a. Close the outlet valve.
b. Check and rule out.
c. Replace the bearings.
d. Voltage stabilization.

6. Water pump leaks

a. Mechanical seal wear.
b. The pump body has sand holes or cracks.
c. The sealing surface is uneven.
d. The installation bolts are loose.

a. Replace.
b. Welding repair or replacement.
c. Trimming.
d. Fasten.

Selection Information Required

Please provide medium, concentration, flow, total head or pressure, temperature, viscosity or solids, voltage, frequency and installation method. DFIN Pump will confirm the suitable model and materials.

Catalog reference: authorized YZJ product data · Model ISW

SELECTION SUPPORT

Application-based pump selection

Send the liquid, flow, head or pressure, temperature, solids, installation, power supply and destination for a verified recommendation.

Discuss this application
NEED SELECTION SUPPORT?

Send us your duty point. Our engineers will recommend a matched pump.

Talk to an engineer