Reference image. Final construction follows the confirmed model and quotation.
Vertical Multistage Pumps
GDL Vertical Inline Multistage Centrifugal Pump
Model: GDL
GDL Vertical Inline Multistage Centrifugal Pump is designed for clean-water transfer, pressure boosting, circulation and general industrial service. DFIN Pump provides model verification, material selection and technical support based on the actual duty point.
TECHNICAL DATA
Specifications, performance and construction
Confirm the final operating point, materials, motor and connection standard before ordering.
Product Overview
GDL Vertical Inline Multistage Centrifugal Pump is an industrial centrifugal pump selected for clean-water transfer, pressure boosting, circulation and general industrial service. The final configuration should be verified against the actual liquid, duty point, temperature, installation and power supply.
Typical Applications
Clean-water transfer, pressure boosting, circulation and general industrial service.
Design Features
- Compact hydraulic design
- Stable flow with low vibration
- Multiple materials and motor options
- Model and material selection supported by DFIN Pump engineers
Extracted Operating Data
- :≤2.5Mpa
- :-15-+120℃
- :2-160m3/h
- :1.1-90kw
Values are reference data from the authorized source catalog. Confirm the selected model before ordering.
Technical Performance Data
| 1 | Pump body | 11 | Coupling | |
| 2 | Tighten the bolts | 12 | Connector | |
| 3 | outer cylinder | 13 | Air nozzle | |
| 4 | impeller | 14 | mechanical seal | |
| 5 | Impeller block sleeve | 15 | axis | |
| 6 | Bushing | 16 | middle section | |
| 7 | gasket | 17 | Bushing nut | |
| 8 | nut | 18 | bush | |
| 9 | pin | 19 | Return pipe parts | |
| 10 | Motor |
|
|
| Model | Stages | Flow | Head | Speed | Motor Power | Efficiency | RequiredNPSHr | Weight |
| m3/h | M | r/min | kw | % | NPSH | KG | ||
| 25GDL2-12 | 3 | 2 | 36 | 2900 | 1.1 | 30 | 2.9 | 58 |
| 25GDL2-12 | 4 | 2 | 48 | 2900 | 1.1 | 30 | 2.9 | 62 |
| 25GDL2-12 | 5 | 2 | 60 | 2900 | 2 | 30 | 2.9 | 68 |
| 25GDL2-12 | 6 | 2 | 72 | 2900 | 2 | 30 | 2.9 | 72 |
| 25GDL2-12 | 7 | 2 | 84 | 2900 | 2 | 30 | 2.9 | 78 |
| 25GDL2-12 | 8 | 2 | 96 | 2900 | 2.2 | 30 | 2.9 | 82 |
| 25GDL2-12 | 9 | 2 | 108 | 2900 | 2 | 30 | 2.9 | 86 |
| 25GDL2-12 | 10 | 2 | 120 | 2900 | 3 | 30 | 2.9 | 98 |
| 25GDL2-12 | 11 | 2 | 132 | 2900 | 3 | 30 | 2.9 | 102 |
| 25GDL2-12 | 12 | 2 | 144 | 2900 | 3 | 30 | 2.9 | |
| 25GDL2-12 | 13 | 2 | 156 | 2900 | 4 | 30 | 2.9 | |
| 25GDL2-12 | 14 | 2 | 168 | 2900 | 4 | 30 | 2.9 | |
| 25GDL2-12 | 15 | 2 | 180 | 2900 | 4 | 30 | 2.9 | |
| Model | Stages | Flow | Head | Speed | Motor Power | Efficiency | RequiredNPSHr | Weight |
| m3/h | M | r/min | kw | % | NPSH | KG | ||
| 25GDL4-11 | 3 | 4 | 33 | 2900 | 1.1 | 42 | 2.9 | 58 |
| 25GDL4-11 | 4 | 4 | 44 | 2900 | 1.5 | 42 | 2.9 | 65 |
| 25GDL4-11 | 5 | 4 | 55 | 2900 | 2.2 | 42 | 2.9 | 72 |
| 25GDL4-11 | 6 | 4 | 66 | 2900 | 2.2 | 42 | 2.9 | 76 |
| 25GDL4-11 | 7 | 4 | 77 | 2900 | 3 | 42 | 2.9 | 86 |
| 25GDL4-11 | 8 | 4 | 88 | 2900 | 3 | 42 | 2.9 | 90 |
| 25GDL4-11 | 9 | 4 | 99 | 2900 | 3 | 42 | 2.9 | 94 |
| 25GDL4-11 | 10 | 4 | 110 | 2900 | 4 | 42 | 2.9 | 110 |
| 25GDL4-11 | 11 | 4 | 121 | 2900 | 4 | 42 | 2.9 | 114 |
| 25GDL4-11 | 12 | 4 | 132 | 2900 | 4 | 42 | 2.9 | |
| 25GDL4-11 | 13 | 4 | 143 | 2900 | 4 | 42 | 2.9 | |
| 25GDL4-11 | 14 | 4 | 154 | 2900 | 5.5 | 42 | 2.9 | |
| 25GDL4-11 | 15 | 4 | 165 | 2900 | 5.5 | 42 | 2.9 | |
| Model | Stages | Flow | Head | Speed | Motor Power | Efficiency | RequiredNPSHr | Weight |
| m3/h | M | r/min | kw | % | NPSH | KG | ||
| 40GDL6-12 | 3 | 6 | 36 | 2900 | 1.5 | 52 | 2.9 | 72 |
| 40GDL6-12 | 4 | 6 | 48 | 2900 | 2.2 | 52 | 2.9 | 78 |
| 40GDL6-12 | 5 | 6 | 60 | 2900 | 2.2 | 52 | 2.9 | 82 |
| 40GDL6-12 | 6 | 6 | 72 | 2900 | 3 | 52 | 2.9 | 92 |
| 40GDL6-12 | 7 | 6 | 84 | 2900 | 3 | 52 | 2.9 | 96 |
| 40GDL6-12 | 8 | 6 | 96 | 2900 | 4 | 52 | 2.9 | 112 |
| 40GDL6-12 | 9 | 6 | 108 | 2900 | 4 | 52 | 2.9 | 116 |
| 40GDL6-12 | 10 | 6 | 120 | 2900 | 4 | 52 | 2.9 | 120 |
| 40GDL6-12 | 11 | 6 | 132 | 2900 | 5.5 | 52 | 2.9 | 140 |
| 40GDL6-12 | 12 | 6 | 144 | 2900 | 5.5 | 52 | 2.9 | |
| 40GDL6-12 | 13 | 6 | 156 | 2900 | 7.5 | 52 | 2.9 | |
| 40GDL6-12 | 14 | 6 | 168 | 2900 | 7.5 | 52 | 2.9 | |
| 40GDL6-12 | 15 | 6 | 180 | 2900 | 7.5 | 52 | 2.9 | |
| Model | Stages | Flow | Head | Speed | Motor Power | Efficiency | RequiredNPSHr | Weight |
| m3/h | M | r/min | kw | % | NPSH | KG | ||
| 50GDL12-15 | 2 | 12 | 30 | 2900 | 2.2 | 57 | 3.5 | 113 |
| 50GDL12-15 | 3 | 12 | 45 | 2900 | 3 | 57 | 3.5 | 129 |
| 50GDL12-15 | 4 | 12 | 60 | 2900 | 4 | 57 | 3.5 | 149 |
| 50GDL12-15 | 5 | 12 | 75 | 2900 | 5.5 | 57 | 3.5 | 181 |
| 50GDL12-15 | 6 | 12 | 90 | 2900 | 5.5 | 57 | 3.5 | 190 |
| 50GDL12-15 | 7 | 12 | 105 | 2900 | 7.5 | 57 | 3.5 | 204 |
| 50GDL12-15 | 8 | 12 | 120 | 2900 | 7.5 | 57 | 3.5 | 212 |
| 50GDL12-15 | 9 | 12 | 135 | 2900 | 11 | 57 | 3.5 | 265 |
| 50GDL12-15 | 10 | 12 | 150 | 2900 | 11 | 57 | 3.5 | 273 |
| Model | Stages | Flow | Head | Speed | Motor Power | Efficiency | RequiredNPSHr | Weight |
| m3/h | M | r/min | kw | % | NPSH | KG | ||
| 50GDL12-25 | 1 | 12 | 25 | 2900 | 2.2 | 57 | 3.5 | 105 |
| 50GDL12-25 | 2 | 12 | 50 | 2900 | 4 | 57 | 3.5 | 119 |
| 50GDL12-25 | 3 | 12 | 75 | 2900 | 5.5 | 57 | 3.5 | 138 |
| 50GDL12-25 | 4 | 12 | 100 | 2900 | 7.5 | 57 | 3.5 | 157 |
| 50GDL12-25 | 5 | 12 | 125 | 2900 | 11 | 57 | 3.5 | 184 |
| 50GDL12-25 | 6 | 12 | 150 | 2900 | 11 | 57 | 3.5 | 191 |
| 50GDL12-25 | 7 | 12 | 175 | 2900 | 15 | 57 | 3.5 | 210 |
| 50GDL12-25 | 8 | 12 | 200 | 2900 | 15 | 57 | 3.5 | 229 |
| Model | Stages | Flow | Head | Speed | Motor Power | Efficiency | RequiredNPSHr | Weight |
| m3/h | M | r/min | kw | % | NPSH | KG | ||
| 50GDL18-15 | 2 | 18 | 30 | 2900 | 3 | 63 | 4 | 122 |
| 50GDL18-15 | 3 | 18 | 45 | 2900 | 4 | 63 | 4 | 142 |
| 50GDL18-15 | 4 | 18 | 60 | 2900 | 5.5 | 63 | 4 | 175 |
| 50GDL18-15 | 5 | 18 | 75 | 2900 | 7.5 | 63 | 4 | 189 |
| 50GDL18-15 | 6 | 18 | 90 | 2900 | 7.5 | 63 | 4 | 198 |
| 50GDL18-15 | 7 | 18 | 105 | 2900 | 11 | 63 | 4 | 252 |
| 50GDL18-15 | 8 | 18 | 120 | 2900 | 11 | 63 | 4 | 261 |
| 50GDL18-15 | 9 | 18 | 135 | 2900 | 15 | 63 | 4 | 280 |
| 50GDL18-15 | 10 | 18 | 150 | 2900 | 15 | 63 | 4 | 289 |
| Model | Stages | Flow | Head | Speed | Motor Power | Efficiency | RequiredNPSHr | Weight |
| m3/h | M | r/min | kw | % | NPSH | KG | ||
| 50GDL18-24 | 1 | 18 | 24 | 2900 | 3 | 63 | 4 | 122 |
| 50GDL18-24 | 2 | 18 | 48 | 2900 | 4 | 63 | 4 | 142 |
| 50GDL18-24 | 3 | 18 | 72 | 2900 | 7.5 | 63 | 4 | 175 |
| 50GDL18-24 | 4 | 18 | 96 | 2900 | 11 | 63 | 4 | 230 |
| 50GDL18-24 | 5 | 18 | 120 | 2900 | 11 | 63 | 4 | 247 |
| 50GDL18-24 | 6 | 18 | 144 | 2900 | 15 | 63 | 4 | 265 |
| 50GDL18-24 | 7 | 18 | 168 | 2900 | 18.5 | 63 | 4 | 274 |
| 50GDL18-24 | 8 | 18 | 192 | 2900 | 22 | 63 | 4 | 301 |
| Model | Stages | Flow | Head | Speed | Motor Power | Efficiency | RequiredNPSHr | Weight |
| m3/h | M | r/min | kw | % | NPSH | KG | ||
| 65GDL24-12 | 2 | 24 | 24 | 2900 | 3 | 63 | 4 | 122 |
| 65GDL24-12 | 3 | 24 | 36 | 2900 | 4 | 63 | 4 | 142 |
| 65GDL24-12 | 4 | 24 | 48 | 2900 | 5.5 | 63 | 4 | 175 |
| 65GDL24-12 | 5 | 24 | 60 | 2900 | 7.5 | 63 | 4 | 189 |
| 65GDL24-12 | 6 | 24 | 72 | 2900 | 7.5 | 63 | 4 | 252 |
| 65GDL24-12 | 7 | 24 | 84 | 2900 | 11 | 63 | 4 | 261 |
| 65GDL24-12 | 8 | 24 | 96 | 2900 | 11 | 63 | 4 | 280 |
| 65GDL24-12 | 9 | 24 | 108 | 2900 | 15 | 63 | 4 | 289 |
| 65GDL24-12 | 10 | 24 | 120 | 2900 | 15 | 63 | 4 | 298 |
| 65GDL24-12 | 11 | 24 | 132 | 2900 | 15 | 63 | 4 | 317 |
| 65GDL24-12 | 12 | 24 | 144 | 2900 | 18.5 | 63 | 4 | 346 |
| Model | Stages | Flow | Head | Speed | Motor Power | Efficiency | RequiredNPSHr | Weight |
| m3/h | M | r/min | kw | % | NPSH | KG | ||
| 65GDL24-24 | 1 | 24 | 24 | 2900 | 3 | 63 | 4 | 122 |
| 65GDL24-24 | 2 | 24 | 48 | 2900 | 5.5 | 63 | 4 | 175 |
| 65GDL24-24 | 3 | 24 | 72 | 2900 | 7.5 | 63 | 4 | 189 |
| 65GDL24-24 | 4 | 24 | 96 | 2900 | 11 | 63 | 4 | 262 |
| 65GDL24-24 | 5 | 24 | 120 | 2900 | 15 | 63 | 4 | 317 |
| 65GDL24-24 | 6 | 24 | 144 | 2900 | 18.5 | 63 | 4 | 346 |
| Model | Stages | Flow | Head | Speed | Motor Power | Efficiency | RequiredNPSHr | Weight |
| m3/h | M | r/min | kw | % | NPSH | KG | ||
| 80GDL36-12 | 2 | 36 | 24 | 2900 | 4 | 71 | 4.2 | 193 |
| 80GDL36-12 | 3 | 36 | 36 | 2900 | 5.5 | 71 | 4.2 | 227 |
| 80GDL36-12 | 4 | 36 | 48 | 2900 | 7.5 | 71 | 4.2 | 244 |
| 80GDL36-12 | 5 | 36 | 60 | 2900 | 11 | 71 | 4.2 | 292 |
| 80GDL36-12 | 6 | 36 | 72 | 2900 | 11 | 71 | 4.2 | 302 |
| 80GDL36-12 | 7 | 36 | 84 | 2900 | 15 | 71 | 4.2 | 322 |
| 80GDL36-12 | 8 | 36 | 96 | 2900 | 15 | 71 | 4.2 | 332 |
| 80GDL36-12 | 9 | 36 | 108 | 2900 | 18.5 | 71 | 4.2 | 365 |
| 80GDL36-12 | 10 | 36 | 120 | 2900 | 18.5 | 71 | 4.2 | 375 |
| Model | Stages | Flow | Head | Speed | Motor Power | Efficiency | RequiredNPSHr | Weight |
| m3/h | M | r/min | kw | % | NPSH | KG | ||
| 80GDL36-24 | 1 | 36 | 24 | 2900 | 4 | 71 | 4.2 | 193 |
| 80GDL36-24 | 2 | 36 | 48 | 2900 | 7.5 | 71 | 4.2 | 193 |
| 80GDL36-24 | 3 | 36 | 72 | 2900 | 11 | 71 | 4.2 | 227 |
| 80GDL36-24 | 4 | 36 | 96 | 2900 | 15 | 71 | 4.2 | 244 |
| 80GDL36-24 | 5 | 36 | 120 | 2900 | 18.5 | 71 | 4.2 | 292 |
| Model | Stages | Flow | Head | Speed | Motor Power | Efficiency | RequiredNPSHr | Weight |
| m3/h | M | r/min | kw | % | NPSH | KG | ||
| 80GDL54-14 | 2 | 54 | 28 | 2900 | 7.5 | 73 | 4 | 218 |
| 80GDL54-14 | 3 | 54 | 42 | 2900 | 11 | 73 | 4 | 267 |
| 80GDL54-14 | 4 | 54 | 56 | 2900 | 15 | 73 | 4 | 287 |
| 80GDL54-14 | 5 | 54 | 70 | 2900 | 18.5 | 73 | 4 | 320 |
| 80GDL54-14 | 6 | 54 | 84 | 2900 | 18.5 | 73 | 4 | 330 |
| 80GDL54-14 | 7 | 54 | 98 | 2900 | 22 | 73 | 4 | 373 |
| 80GDL54-14 | 8 | 54 | 112 | 2900 | 30 | 73 | 4 | 400 |
| 80GDL54-14 | 9 | 54 | 126 | 2900 | 30 | 73 | 4 | 421 |
| 80GDL54-14 | 10 | 54 | 140 | 2900 | 37 | 73 | 4 | 432 |
| Model | Stages | Flow | Head | Speed | Motor Power | Efficiency | RequiredNPSHr | Weight |
| m3/h | M | r/min | kw | % | NPSH | KG | ||
| 80GDL54-28 | 1 | 54 | 28 | 2900 | 7.5 | 73 | 4 | 218 |
| 80GDL54-28 | 2 | 54 | 56 | 2900 | 15 | 73 | 4 | 287 |
| 80GDL54-28 | 3 | 54 | 84 | 2900 | 18.5 | 73 | 4 | 320 |
| 80GDL54-28 | 4 | 54 | 112 | 2900 | 30 | 73 | 4 | 453 |
| 80GDL54-28 | 5 | 54 | 140 | 2900 | 37 | 73 | 4 | 493 |
| Model | Stages | Flow | Head | Speed | Motor Power | Efficiency | RequiredNPSHr | Weight |
| m3/h | M | r/min | kw | % | NPSH | KG | ||
| 100GDL72-14 | 2 | 72 | 28 | 2900 | 11 | 73 | 4.5 | 276 |
| 100GDL72-14 | 3 | 72 | 42 | 2900 | 15 | 73 | 4.5 | 298 |
| 100GDL72-14 | 4 | 72 | 56 | 2900 | 18.5 | 73 | 4.5 | 336 |
| 100GDL72-14 | 5 | 72 | 70 | 2900 | 22 | 73 | 4.5 | 381 |
| 100GDL72-14 | 6 | 72 | 84 | 2900 | 30 | 73 | 4.5 | 453 |
| 100GDL72-14 | 7 | 72 | 98 | 2900 | 30 | 73 | 4.5 | 466 |
| 100GDL72-14 | 8 | 72 | 112 | 2900 | 37 | 73 | 4.5 | 493 |
| 100GDL72-14 | 9 | 72 | 126 | 2900 | 37 | 73 | 4.5 | 582 |
| 100GDL72-14 | 10 | 72 | 140 | 2900 | 45 | 73 | 4.5 | 595 |
| Model | Stages | Flow | Head | Speed | Motor Power | Efficiency | RequiredNPSHr | Weight |
| m3/h | M | r/min | kw | % | NPSH | KG | ||
| 100GDL72-28 | 1 | 72 | 28 | 2900 | 11 | 73 | 4.5 | 276 |
| 100GDL72-28 | 2 | 72 | 56 | 2900 | 18.5 | 73 | 4.5 | 336 |
| 100GDL72-28 | 3 | 72 | 84 | 2900 | 30 | 73 | 4.5 | 453 |
| 100GDL72-28 | 4 | 72 | 112 | 2900 | 37 | 73 | 4.5 | 582 |
| 100GDL72-28 | 5 | 72 | 140 | 2900 | 45 | 73 | 4.5 | 595 |
| Model | Stages | Flow | Head | Speed | Motor Power | Efficiency | RequiredNPSHr | Weight |
| m3/h | M | r/min | kw | % | NPSH | KG | ||
| 100GDL100-30 | 1 | 100 | 30 | 2900 | 18.5 | 73 | 4.5 | 336 |
| 100GDL100-30 | 2 | 100 | 60 | 2900 | 30 | 73 | 4.5 | 453 |
| 100GDL100-30 | 3 | 100 | 90 | 2900 | 37 | 73 | 4.5 | 493 |
| 100GDL100-30 | 4 | 100 | 120 | 2900 | 55 | 73 | 4.5 | 640 |
| 100GDL100-30 | 5 | 100 | 150 | 2900 | 75 | 73 | 4.5 | 840 |
| 100GDL100-30 | 6 | 100 | 180 | 2900 | 75 | 73 | 4.5 | 855 |
| 100GDL100-30 | 7 | 100 | 210 | 2900 | 90 | 73 | 4.5 | 870 |
| Model | Stages | Flow | Head | Speed | Motor Power | Efficiency | RequiredNPSHr | Weight |
| m3/h | M | r/min | kw | % | NPSH | KG | ||
| 125GDL100-20 | 2 | 108 | 40 | 2900 | 18.5 | 74 | 4.5 | 292 |
| 125GDL100-20 | 3 | 108 | 60 | 2900 | 30 | 74 | 4.5 | 430 |
| 125GDL100-20 | 4 | 108 | 80 | 2900 | 37 | 74 | 4.5 | 463 |
| 125GDL100-20 | 5 | 108 | 100 | 2900 | 45 | 74 | 4.5 | 555 |
| 125GDL100-20 | 6 | 108 | 120 | 2900 | 55 | 74 | 4.5 | 640 |
| 125GDL100-20 | 7 | 108 | 140 | 2900 | 75 | 74 | 4.5 | 840 |
| 125GDL100-20 | 8 | 108 | 160 | 2900 | 75 | 74 | 4.5 | 855 |
| 125GDL100-20 | 9 | 108 | 180 | 2900 | 90 | 74 | 4.5 | 870 |
| 125GDL100-20 | 10 | 108 | 200 | 2900 | 90 | 74 | 4.5 | 955 |
| Model | Stages | Flow | Head | Speed | Motor Power | Efficiency | RequiredNPSHr | Weight |
| m3/h | M | r/min | kw | % | NPSH | KG | ||
| 125GDL100-30 | 1 | 100 | 30 | 2900 | 18.5 | 74 | 4.5 | 336 |
| 125GDL100-30 | 2 | 100 | 60 | 2900 | 30 | 74 | 4.5 | 453 |
| 125GDL100-30 | 3 | 100 | 90 | 2900 | 37 | 74 | 4.5 | 493 |
| 125GDL100-30 | 4 | 100 | 120 | 2900 | 55 | 74 | 4.5 | 640 |
| 125GDL100-30 | 5 | 100 | 150 | 2900 | 75 | 74 | 4.5 | 840 |
| 125GDL100-30 | 6 | 100 | 180 | 2900 | 75 | 74 | 4.5 | 855 |
| 125GDL100-30 | 7 | 100 | 210 | 2900 | 90 | 74 | 4.5 | 870 |
| Model | Stages | Flow | Head | Speed | Motor Power | Efficiency | RequiredNPSHr | Weight |
| m3/h | M | r/min | kw | % | NPSH | KG | ||
| 150GDL160-20 | 2 | 160 | 40 | 2900 | 30 | 78 | 4.5 | 422 |
| 150GDL160-20 | 3 | 160 | 60 | 2900 | 37 | 78 | 4.5 | 452 |
| 150GDL160-20 | 4 | 160 | 80 | 2900 | 55 | 78 | 4.5 | 613 |
| 150GDL160-20 | 5 | 160 | 100 | 2900 | 75 | 78 | 4.5 | 820 |
| 150GDL160-20 | 6 | 160 | 120 | 2900 | 75 | 78 | 4.5 | 836 |
| 150GDL160-20 | 7 | 160 | 140 | 2900 | 90 | 78 | 4.5 | 922 |
| Model | Stages | Flow | Head | Speed | Motor Power | Efficiency | RequiredNPSHr | Weight |
| m3/h | M | r/min | kw | % | NPSH | KG | ||
| 150GDL160-30 | 1 | 160 | 30 | 2900 | 30 | 78 | 4.5 | 422 |
| 150GDL160-30 | 2 | 160 | 60 | 2900 | 37 | 78 | 4.5 | 452 |
| 150GDL160-30 | 3 | 160 | 90 | 2900 | 55 | 78 | 4.5 | 613 |
| 150GDL160-30 | 4 | 160 | 120 | 2900 | 75 | 78 | 4.5 | 820 |
| 150GDL160-30 | 5 | 160 | 150 | 2900 | 90 | 78 | 4.5 | 922 |
| 150GDL160-30 | 6 | 160 | 180 | 2900 | 110 | 78 | 4.5 | 1210 |
| 150GDL160-30 | 7 | 160 | 210 | 2900 | 132 | 78 | 4.5 | 1360 |
| Model | H1 | L | B | 4-φd1 | Inlet flange(J) | ||
| DN | N-φD2 | φD | |||||
| 25GDL | 60 | 00 | 200 | 4-φ18 | 25 | 4-φ14 | 85 |
| 40GDL | 80 | 60 | 235 | 4-φ18 | 40 | 4-φ18 | 110 |
| 50GDL | 100 | 60 | 235 | 4-φ18 | 50 | 4-φ18 | 125 |
| 65GDL | 110 | 60 | 235 | 4-φ18 | 65 | 4-φ18 | 145 |
| 80GDL | 130 | 420 | 00 | 4-φ18 | 80 | 8-φ18 | 160 |
| 100GDL | 160 | 520 | 50 | 4-φ18 | 100 | 8-φ18 | 180 |
| 125GDL | 160 | 500 | 400 | 4-φ18 | 125 | 8-φ18 | 210 |
| 150GDL | 180 | 600 | 400 | 4-φ18 | 150 | 8-φ22 | 245 |
| Fault phenomena | Possible causes | Troubleshooting |
|
1. The water pump does not discharge water |
The water inlet valve is not opened, the inlet and outlet pipes are blocked, and the impeller flow path is blocked. The motor is running in the wrong direction, the motor is missing phase and the speed is very slow. Air leakage in suction pipe The pump is not filled with liquid and there is air in the pump chamber. Inlet water supply is insufficient, Suction Lift is too high, and bottom valve is leaking The pipeline resistance is too large and the pump selection is inappropriate. |
Check and remove obstructions Adjust Motor steering and tighten Motor wiring Tighten each sealing surface and remove air Open the pump cover or open the exhaust valve to exhaust the air Shutdown inspection and adjustment Reduce pipeline bends and reselect pumps |
|
2. Insufficient water pump flow |
First, check for one reason. Pipes, pump flow channels or impellers are partially blocked, scale deposits... Voltage is low Impeller wear |
Press 1 first to exclude Remove obstructions and readjust valve opening voltage stabilization Replace impeller |
|
3. Power is too large |
Use beyond rated flow Suction Lift is too high Pump bearing wear |
Adjust Flow and close the outlet valve reduce Replace bearings |
|
4. Noise and vibration |
Pipeline support is unstable liquid mixed with gas cavitation Bearing damage Motor overload operation |
Stable pipeline Increase suction pressure, exhaust Reduce vacuum Replace bearings Adjustment press 5 |
|
5. Motor fever |
Flow is too large and overloaded local friction Motor bearing damage Insufficient Voltage |
Turn off the outlet valve Check exclusions Replace bearings voltage stabilization |
|
6. Water pump leaks |
Mechanical seal wear The pump body has sand holes or cracks The sealing surface is uneven Loose mounting bolts |
replace Welding repair or replacement Trim fasten |
Selection Information Required
Please provide medium, concentration, flow, total head or pressure, temperature, viscosity or solids, voltage, frequency and installation method. DFIN Pump will confirm the suitable model and materials.
Catalog reference: authorized YZJ product data · Model GDL
SELECTION SUPPORT
Application-based pump selection
Send the liquid, flow, head or pressure, temperature, solids, installation, power supply and destination for a verified recommendation.
Discuss this application