Modelo: MNX-F-453

MNX-F-453 Bomba de accionamiento magnético. 50; 40; 50Hz: 530; 60Hz: 530.

Discutir esta aplicación

DATOS TÉCNICOS

Especificaciones, rendimiento y construcción.

Los valores del catálogo son datos de referencia. El punto de funcionamiento final debe compararse con el sistema real y el modelo seleccionado.

MNX-F-453 Magnetic Drive Pump

MNX-F-453 is a MNX magnetic series magnetic drive pump available through DFIN PUMP. The model-specific catalogue data below provides a starting point for technical selection. Quote the complete model designation when requesting a quotation; similar series names do not establish interchangeable components or identical duty.

Model-specific technical data

ParameterCatalogue value
Inlet (mm)50
Outlet (mm)40
Catalogue full-flow value (L/min)50Hz: 530; 60Hz: 530
Catalogue full-head value (m)50Hz: 29; 60Hz: 30
Motor power2.2 kW

Catalog full-flow and full-head values are separate characteristics, not a guaranteed simultaneous operating point. Check the performance curve and selected configuration.

Performance and configuration

Full-flow and full-head catalogue values must not be interpreted as a guaranteed simultaneous duty. Obtain a performance curve for the selected configuration. Electrical values, where provided, apply only to the listed configuration. Missing frequency, motor rating or connection information is not inferred from other models.

Application assessment

Provide the liquid composition, concentration, temperature, density, viscosity, solids content and required operating schedule. Confirm compatibility of all wetted components with the actual liquid. General series descriptions are not a chemical compatibility certificate. Materials, dry-running capability, hazardous-area approvals and sanitary compliance require explicit confirmation for the offered equipment.

Installation planning

Confirm the final connection standard, outline drawing, mounting arrangement and maintenance clearance before completing pipework. The catalogue connection sizes do not establish flange drilling or thread standards. Account for static lift, pipe friction, valve losses and downstream pressure when defining the required duty. Provide safe isolation and independently supported pipework as appropriate to the confirmed equipment.

Commissioning and maintenance

Follow the instructions supplied with the selected equipment. Confirm the electrical supply, protection and rotation requirements before starting. Check the actual flow, pressure and motor load against the confirmed operating envelope. Stop and investigate unusual vibration, leakage, overheating or loss of liquid supply. Isolate, depressurize and make the equipment safe before inspection or replacement of service parts.

Quotation checklist

Send DFIN PUMP the full model MNX-F-453, required duty, liquid properties, installation details, supply voltage and frequency, connection requirements and requested accessories. For dosing service, include the discharge pressure and control method; for filtration service, include the required retention level and contamination load. Final materials, dimensions, options and delivery scope follow the confirmed quotation.

Product artwork represents the corresponding series. Model-specific values are listed in the technical table; illustration geometry is not a dimensioned installation drawing.

Magnetic-drive selection

For a magnetic-drive arrangement, confirm the coupling load, liquid lubrication requirements and permitted operating envelope with the supplier. Do not assume that a series photograph establishes a particular containment-shell material or dry-running protection. A duty review should address inlet conditions, viscosity and the temperature of the liquid as well as the required flow.

Selection question: Can this model handle every chemical?

No. Provide the exact chemical and concentration so that the offered wetted materials and seals can be checked. A magnetic-drive designation alone does not establish chemical compatibility.

Request the MNX-F-453 configuration

The table on this page refers specifically to MNX-F-453. If frequency is not listed, confirm it in the quotation. Ask for a dimensioned drawing and an itemized delivery scope before approving a replacement or a new installation.

SOPORTE DE SELECCIÓN

Selección de bombas basada en la aplicación

Envíe las condiciones reales de funcionamiento en lugar de solo el nombre del modelo. Nuestros ingenieros compararán los requisitos del punto de trabajo, la construcción y la instalación antes de la cotización.

Discutir esta aplicación
¿NECESITAS AYUDA PARA LA SELECCIÓN?

Indíquenos su punto de funcionamiento. Nuestros ingenieros le recomendarán la bomba adecuada.

Hable con un ingeniero