Pemilihan pompa & dukungan pasokan global+86 151 2119 9987 · dfin88@dfinsewagepump.com
Pompa Seri 2CY/Pompa Oli

Gambar referensi. Konstruksi akhir mengikuti model dan kutipan yang dikonfirmasi.

Pompa pemindah minyak

Pompa Seri 2CY/Pompa Oli

Model: 2CY

Pompa Seri 2CY/Pompa Oli dirancang untuk transfer bahan bakar, oli pelumas, dan produk minyak bumi umum. DFIN Pump menyediakan verifikasi model, pemilihan material, dan dukungan teknis berdasarkan titik kerja aktual.

Diskusikan aplikasi ini

DATA TEKNIS

Spesifikasi, kinerja dan konstruksi

Nilai katalog adalah data referensi. Titik pengoperasian akhir harus dibandingkan dengan sistem sebenarnya dan model yang dipilih.

Ikhtisar produk

2CY Series Pump/ Oil Pump is an industrial oil transfer pump selected for fuel, lubricating oil and general petroleum-product transfer. The final configuration should be verified against the actual liquid, duty point, temperature, installation and power supply.

Aplikasi umum

Fuel, lubricating oil and general petroleum-product transfer.

Fitur desain

  • Steady delivery
  • Compact construction
  • Multiple drive and seal options
  • Insinyur DFIN Pump mendukung pemilihan model dan material

Extracted Operating Data

  • , 10°E(75C·S·t) , 300℃

Nilai merupakan data referensi dari katalog sumber yang diizinkan. Konfirmasikan model yang dipilih sebelum memesan.

Data kinerja teknis

Model

Port Size(mm) Flow (L/min) Eject pressure (MPa) Suction Lift(m) Motor Power(KW)
2CY-1.1/14.5-2 3/4 18.3 1.45 5 1.5
2CY-2/14.5-2 3/4 33.3 1.45 5 2.2
2CY-3.3/3.3-2 1″ 55 0.33 5 1.5
2CY-5/3.5-2 1″ 55 0.33 5 2.2
2CY-5/5-2 1 1/2″ 83.3 0.33 5 2.2
2CY-8/3.3-2 1 1/2″ 83.3 0.33 5 3
2CY-12/1.3-22 2″ 200 0.33 5 4
2CY-12/3.3-2 2″ 200 0.33 5 4
2CY-12/6-2 2″ 200 0.33 5 5.5
2CY-18/10-2 2″ 200 0.33 5 5.5
2CY-18/3.6-2 2 1/2″ 200 0.33 5 7.5
2CY-18/3.6-2 3″ 300 0.33 5 5.5
2CY-18/6-2 3″ 300 0.33 5 7.5
2CY-29/3.6-2 3″ 483.3 0.33 5 7.5
2CY-29/3.6-2 3″ 483.3 0.33 5 11
2CY-38/2.8-2 4″ 633 0.28 5 11
2CY-38/8-2 4″ 633 0.28 5 22
 2CY-60/3-2 4″ 960 0.3 5 18.5
2CY-60/6-2 4″ 960 0.3 5 30

Phenomenon

Causes

Troubleshooting

No discharge or
Less oil.

1. Inhalation heights exceeding rated values
Inhalation of leaks in the pipeline
3. The rotation is not in the right direction
4. Inhalation pipe congestion or valve closure
5. Increased viscosity due to low liquid temperatures
6. Serious damage to gears and pumps

1. Increased or reduced pipe resistance
2. Check for leaks of gas or fluid at the interfaces and seal sealed villages such as asbestos
3. Correct the direction of the pump
Clear the plugs and open the valves.
5. Preheating liquids, if not possible, reduced discharge pressure and reduced discharges
6. Dismantling and replacement of other relevant items

Seal leaks.

1. The axle seal is not adjusted
Sealring wears, increased gap
3. Modular sealing of gill rings and motion rings with worn face damage or defects such as graft marks
4. Springs loose

Readjustment
2. Tightening nuts or replacing seals
3. Replacement of motion rings or grinding
Change springs

Noise or
Very vibrating.

Inhalation or filter blocking
2. Sorpture into the oil tank
Pipeline into air
There's too much resistance to venting.
5. Serious wear and tear on gears, bearings or sides
6. Too much viscosity of inhalation fluid

1. Clearing the net of contamination
2. Inhalation tubes should reach about 0.5 metres into the tank
3. Check for connections and seal them
4. Inspection of pipes and valves and discharge of congestion or adjustment of pipes to reduce bends, valves, etc.
5. Replacement of new gears, bearings or sides
Treatment under Article 6 of Article 1

Informasi yang diperlukan untuk pemilihan

Berikan media, konsentrasi, debit, head total atau tekanan, suhu, viskositas atau padatan, tegangan, frekuensi, dan metode pemasangan. DFIN Pump akan mengonfirmasi model dan material yang sesuai.

Catalog reference: product technical data · Model 2CY

DUKUNGAN SELEKSI

Pemilihan pompa berdasarkan aplikasi

Kirimkan kondisi pengoperasian sebenarnya, bukan hanya nama model. Teknisi kami akan membandingkan titik tugas, persyaratan konstruksi dan pemasangan sebelum penawaran.

Diskusikan aplikasi ini
BUTUH BANTUAN SELEKSI?

Kirimkan titik tugas Anda kepada kami. Teknisi kami akan merekomendasikan pompa yang sesuai.

Bicaralah dengan seorang insinyur.