ポンプの選定とグローバルな供給サポート+86 151 2119 9987 · dfin88@dfinsewagepump.com
MZK-65-7.5 プロセスポンプ

参考画像。最終的な施工は確認されたモデルと見積書に従って行われます。

遠心・インラインポンプ

MZK-65-7.5 プロセスポンプ

型式: MZK-65-7.5

MZK-65-7.5 プロセスポンプ. 80; 65; 7.5 HP.

このアプリケーションについて話し合う

技術データ

仕様・性能・構造

カタログ値は参考値です。最終的な動作点は、実際のシステムおよび選択したモデルに対して確認する必要があります。

MZK-65-7.5 Process Pump

MZK-65-7.5 is a MZK series process pump available through DFIN PUMP. The model-specific catalogue data below provides a starting point for technical selection. Quote the complete model designation when requesting a quotation; similar series names do not establish interchangeable components or identical duty.

Model-specific technical data

ParameterCatalogue value
Inlet (mm)80
Outlet (mm)65
Motor power7.5 HP
Catalogue full-flow value (L/min)50Hz: 1030
Catalogue full-head value (m)50Hz: 33

Catalogue values are reference data for the stated configuration. Confirm the offered specification and operating conditions before ordering.

Performance and configuration

Full-flow and full-head catalogue values must not be interpreted as a guaranteed simultaneous duty. Obtain a performance curve for the selected configuration. Electrical values, where provided, apply only to the listed configuration. Missing frequency, motor rating or connection information is not inferred from other models.

Application assessment

Provide the liquid composition, concentration, temperature, density, viscosity, solids content and required operating schedule. Confirm compatibility of all wetted components with the actual liquid. General series descriptions are not a chemical compatibility certificate. Materials, dry-running capability, hazardous-area approvals and sanitary compliance require explicit confirmation for the offered equipment.

Installation planning

Confirm the final connection standard, outline drawing, mounting arrangement and maintenance clearance before completing pipework. The catalogue connection sizes do not establish flange drilling or thread standards. Account for static lift, pipe friction, valve losses and downstream pressure when defining the required duty. Provide safe isolation and independently supported pipework as appropriate to the confirmed equipment.

Commissioning and maintenance

Follow the instructions supplied with the selected equipment. Confirm the electrical supply, protection and rotation requirements before starting. Check the actual flow, pressure and motor load against the confirmed operating envelope. Stop and investigate unusual vibration, leakage, overheating or loss of liquid supply. Isolate, depressurize and make the equipment safe before inspection or replacement of service parts.

Quotation checklist

Send DFIN PUMP the full model MZK-65-7.5, required duty, liquid properties, installation details, supply voltage and frequency, connection requirements and requested accessories. For dosing service, include the discharge pressure and control method; for filtration service, include the required retention level and contamination load. Final materials, dimensions, options and delivery scope follow the confirmed quotation.

Product artwork represents the corresponding series. Model-specific values are listed in the technical table; illustration geometry is not a dimensioned installation drawing.

Process duty assessment

Define the required flow at the total system head, including static elevation and piping losses. Provide liquid properties and inlet conditions for a duty review. The series illustration does not establish materials, dimensions or optional certifications.

Selection question: How is the final duty confirmed?

Ask for the performance curve and operating envelope for the quoted configuration, then compare them with the system requirement. Do not select only by motor power or connection diameter.

Request the MZK-65-7.5 configuration

The table on this page refers specifically to MZK-65-7.5. If frequency is not listed, confirm it in the quotation. Ask for a dimensioned drawing and an itemized delivery scope before approving a replacement or a new installation.

選択のサポート

用途に応じたポンプの選択

機種名だけではなく、実際の使用状況をお送りください。当社のエンジニアは、見積もりの​​前に担当ポイント、構造、設置要件を比較します。

このアプリケーションについて話し合う
選考サポートが必要ですか?

お客様の使用地点をお知らせください。当社のエンジニアが最適なポンプをご提案いたします。

エンジニアに相談する