图片仅供参考,最终结构以确认的型号和报价为准。
磁力泵
MP型磁力循环泵
型号: 按工况确认
MP型磁力循环泵 型号说明 MP型磁力循环泵 磁力驱动循环泵的工作原理是:连接轴和叶轮上装有磁性材料,相互吸引耦合。无需传统的机械轴封,因此实现了完全密封。
咨询此应用技术数据
规格、性能与结构
目录参数仅供参考,最终运行点必须结合实际系统与所选型号核定。
MP type magnetic circulation pump Model meaning
MP type magnetic circulation pump The magnetic drive circulation pump operates because the connecting shaft and impeller are equipped with
magnetic materials to attract and couple to each other. There is no need for a traditional mechanical shaft seal, so it is completely sealed. The
rotational torque of the motor drives the blades to operate through the attraction of the active magnet and the driven magnet.
MP type magnetic circulation pump The biggest disadvantage of the commonly used magnetic drive pumps today is that they are absolutely
forbidden to operate when there is a lack of fluid, otherwise the whole machine will be destroyed, adding unnecessary trouble and annoyance
to the user. It uses a specially designed specially formulated ceramic as the bearing, which has extremely strong wear resistance and corrosion
resistance, ensuring its advanced performance and quality safety. The drive circulation pump generally adopts a shaft seal-less design, which
completely avoids the defects of corrosion and contamination caused by liquid leakage in traditional mechanical shaft seal pumps. It is an ideal
liquid transfer pump for industrial equipment.
MP type magnetic circulation pumpParts
1. Fixing screws and washers
2. Pump shell
3. Pump shaft
4. Impeller
5. Passive magnet
6. Seal ring
7. Isolation sleeve
8. Active magnet
9. Motor
MP type magnetic circulation pump Material
Stainless steel
Reinforced polypropylene
Alumina ceramic
Reinforced polypropylene
Strontium Ferrite
Fluorine rubber
Reinforced polypropylene
Strontium Ferrite
Working purpose of MP type magnetic drive circulation pump
Chemical industry: Sodium carbonate chemical industry (production of hydrochloric acid, hydrofluoric acid, secondary chemicals); production
of fluoride and chemical fertilizers; gas absorption tower reaction liquid circulation; oil refining (sulfuric acid); recovery and regeneration of waste
acids Systems; transport of strong acids between chemical plants and transport vehicles.
Pharmaceutical industry: Production of luminescent chemicals (EL) for semiconductors, pesticides, pharmaceuticals, and water treatment chemicals
Electroplating industry: Circulating and filtering various electroplating solutions.
Photography industry: ready-made photographic systems; development of X-rays, black and white, color, and three-dimensional photographs.
Electrical appliance industry: production of electrolytic capacitors (etching of aluminum films); transport of electrolytes during the manufacturing
process of dry batteries and storage batteries; etching of circuit boards; transport of high-purity chemical liquids during the production of semiconductors.
Metal industry: Alumina film treatment equipment; degreasing and pickling in wire drawing and steel rolling; degreasing and pickling before vehicle
painting; production of titanium oxide and rare earth elements, etc.
Mining: metal smelting (transporting and circulating electrolyte); washing and treatment of waste liquid.
Food industry: production of gluconic acid (hydrochloric acid); refining of cooking oil (sulfuric acid); canned fruit industry (hydrochloric acid).
Medical: Artificial kidneys, heart and lungs, ultrasonic cleaning machines and various medical equipment.
Water treatment: cleaning ion exchange resin; pure water production equipment; seawater desalination equipment.
Pollution control: Adding sewage treatment chemicals to the liquid tank; collecting and transporting waste liquid; waste gas absorption equipment
(deodorization device, desulfurization before discharging waste gas).
Others: Used in silver recycling, wafer manufacturing, experimental factories, refrigerators, beverage machines, domestic boilers, heat exchangers,
solar systems, bleaching and dyeing, laser systems and other fields, and recycled in fountains, fish ponds, and ornamental fish tanks.
MP type magnetic circulation pump Specifications
| model | Standard entrance and exit | Standard entrance and exit | standard output | 电机 | ||||
| Entrance | exit | entrance/exit | living tube | flow | Lift | power | 电压 | |
| mm | mm | mm | mm | L/Min | M | W | V | |
| MP-6R | 14 | 14 | - | - | 2.8/5 | 0.8 | 6 | 220 |
| MP-6RZ | 14 | 14 | - | - | 3.2/4.5 | 0.8 | 6 | 220 |
| MP-10R | 14 | 14 | - | - | 5/8 | 1 | 6 | 220 |
| MP-10RN | 14 | 14 | - | - | 5/8 | 1 | 6 | 220 |
| MP-15R | 16 | 16 | - | - | 8-12 | 1.5 | 10 | 220 |
| MP-15RN | 16 | 16 | - | - | 8-12 | 1.5 | 10 | 220 |
| MP-15RM | - | - | 3-4 | 13 | 8-12 | 1.5 | 10 | 220 |
| MP-20R | 18 | 18 | - | - | 17/22 | 2 | 15 | 220 |
| MP-20RM | - | - | 3-4 | 16 | 17/22 | 2 | 15 | 220 |
| MP-20RX | 26 | 26 | - | - | 30/40 | 1 | 15 | 220 |
| MP-20Z | 18 | 18 | - | - | 7/10 | 4 | 15 | 220 |
| MP-30R | 20 | 20 | - | - | 16/25 | 2.5 | 25 | 220 |
| MP-30RM | - | - | 3-4 | 16 | 16/25 | 2.5 | 25 | 220 |
| MP-30RX | 26 | 26 | - | - | 32/46 | 2 | 25 | 220 |
| MP-30RZ | - | - | 3-4 | 13 | 10-14 | 6 | 25 | 220 |
| MP-40R | 20 | 20 | - | - | 22/34 | 4 | 65 | 220 |
| MP-40RM | - | - | 3-4 | 16 | 22/34 | 4 | 65 | 220 |
| MP-40RX | 26 | 26 | - | - | 47/65 | 2 | 65 | 220 |
| MP-40RXM | - | - | 1 | 20 | 47/65 | 2 | 65 | 220 |
| MP-55R | 26 | 26 | - | - | 30/45 | 4 | 90 | 220/380 |
| MP-55RM | - | - | 1 | 20 | 30/45 | 4 | 90 | 220/380 |
| MP-55RZ | 26 | 26 | - | - | 15/22 | 8 | 90 | 220/380 |
| MP-55RZM | - | - | 1 | 20 | 15/22 | 8 | 90 | 220/380 |
| MP-70R | 26 | 26 | - | - | 50/72 | 4 | 150 | 220/380 |
| MP-70RM | - | - | 1 | 20 | 50/72 | 4 | 150 | 220/380 |
| MP-100R | 26 | 26 | - | - | 60/70 | 7/9 | 250 | 220/380 |
| MP-100RM | - | - | 1 | 20 | 60/70 | 7/9 | 250 | 220/380 |
| MP-100RX | - | - | 11-4 | 32 | 100 | 5 | 250 | 220/380 |
| MP-120R | - | - | 11-2 | 36 | 140 | 6 | 370 | 220/380 |
| MP-120RT | - | - | 21/4 | 48 | 140 | 6 | 370 | 220/380 |
| MP-400CV5-D | - | - | 11/2 | 36 | 150 | 8 | 400 | 380 |
| MP-401CV5-D | - | - | 11/2 | 36 | 120 | 12 | 750 | 380 |
| MP-422CV5-D | - | - | 2 | 1-2 | 160 | 18 | 1500 | 380 |
| MP-423CV5-D | - | - | 2 | 1-2 | 230 | 18 | 2200 | 380 |
MP type magnetic circulation pump Performance curve